跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.33843 · v1

Continuous Foundation-Guided Pseudo-Label Weighting for Breast Ultrasound Domain Adaptation

首次提交 2026-11-25 14:13
版本更新 2026-11-25 14:13
雷达观测 2026-11-26 11:26
arXiv ↗PDF ↗

摘要

Breast ultrasound segmentation models often generalize poorly across scanners, institutions, and patient populations. We investigate continuous foundation-guided pseudo-label weighting for unsupervised domain adaptation (UDA). An exponential-moving-average (EMA) teacher generates target-domain pseudo-labels, while a frozen ultrasound segmentation model (AutoSAMUS) modulates their contribution using a bounded weight that combines the prior's certainty with its probabilistic agreement with the teacher. In contrast to our earlier selective BiRP rule, the proposed formulation supervises every target pixel with a weight in [0.5, 1] and requires no foundation-model inference at test time. We evaluate the method on five public breast ultrasound datasets, spanning three source domains and eleven source-target directions. Under the TransUNet protocol, continuous weighting outperforms both all-pixel EMA and original BiRP on all four BUSI-source targets, and achieves the highest mean Dice and lowest HD95 among the compared methods on all four BUS-BRA-source targets. Results with BrEaST as the source are mixed: continuous weighting performs best on BUSI and comparably to original BiRP on OASBUD, whereas none of the adaptation methods surpasses source-only training on BUS-UCLM. In a separate U-Net pipeline, agreement-only weighting performs comparably to the full formulation, leaving the incremental value of prior certainty unresolved. Because the weighting rule was developed after some target-test results had been examined, we treat the study as exploratory and report adverse as well as favorable outcomes.

作者备注:8 pages, 3 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-25 14:13 · 最新观测版本

Continuous Foundation-Guided Pseudo-Label Weighting for Breast Ultrasound Domain Adaptation

Breast ultrasound segmentation models often generalize poorly across scanners, institutions, and patient populations. We investigate continuous foundation-guided pseudo-label weighting for unsupervised domain adaptation (UDA). An exponential-moving-average (EMA) teacher generates target-domain pseudo-labels, while a frozen ultrasound segmentation model (AutoSAMUS) modulates their contribution using a bounded weight that combines the prior's certainty with its probabilistic agreement with the teacher. In contrast to our earlier selective BiRP rule, the proposed formulation supervises every target pixel with a weight in [0.5, 1] and requires no foundation-model inference at test time. We evaluate the method on five public breast ultrasound datasets, spanning three source domains and eleven source-target directions. Under the TransUNet protocol, continuous weighting outperforms both all-pixel EMA and original BiRP on all four BUSI-source targets, and achieves the highest mean Dice and lowest HD95 among the compared methods on all four BUS-BRA-source targets. Results with BrEaST as the source are mixed: continuous weighting performs best on BUSI and comparably to original BiRP on OASBUD, whereas none of the adaptation methods surpasses source-only training on BUS-UCLM. In a separate U-Net pipeline, agreement-only weighting performs comparably to the full formulation, leaving the incremental value of prior certainty unresolved. Because the weighting rule was developed after some target-test results had been examined, we treat the study as exploratory and report adverse as well as favorable outcomes.

查看此版本解读 →查看此版本原文 ↗