跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2611.34622 · v1

Beyond Pose Control: Anatomically Consistent Ultrasound Video Generation

首次提交 2026-11-26 00:08
版本更新 2026-11-26 00:08
雷达观测 2026-11-26 12:28
arXiv ↗PDF ↗

摘要

Camera-controlled video generation anticipates how a scene appears from new viewpoints by relying on a prior learned implicitly from large-scale data. Ultrasound poses the same problem, with the probe pose as the viewpoint, but under opposite conditions: anatomy offers an explicit prior that every sonographer relies on, whereas tracked scans are too scarce to learn it implicitly. As a result, pose control alone is not enough, and pose-conditioned ultrasound generators produce implausible anatomy in unscanned regions and inconsistent anatomy on revisits. We go beyond pose control and give the generator the two kinds of knowledge that make up a sonographer's mental model. An anatomical prior, built from a population of subjects, guides generation where nothing has been scanned, and is refined online by every generated chunk towards the scanned subject. A 3D latent memory, designed around the cross-sectional physics of ultrasound, compounds the generated slices into a volume of the patient and reslices it at new poses, keeping revisited anatomy consistent. The fine-grained memory enters the generator at the input, while the coarse anatomy prior guides the layout across transformer blocks. Experiments on thyroid, kidney, and lumbar spine show improved visual fidelity, pose following, and anatomical consistency over pose-conditioned and memory-augmented baselines.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只收录了一个版本。收录下一版后,可以对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v1 · 2026-11-26 00:08 · 最新观测版本

Beyond Pose Control: Anatomically Consistent Ultrasound Video Generation

Camera-controlled video generation anticipates how a scene appears from new viewpoints by relying on a prior learned implicitly from large-scale data. Ultrasound poses the same problem, with the probe pose as the viewpoint, but under opposite conditions: anatomy offers an explicit prior that every sonographer relies on, whereas tracked scans are too scarce to learn it implicitly. As a result, pose control alone is not enough, and pose-conditioned ultrasound generators produce implausible anatomy in unscanned regions and inconsistent anatomy on revisits. We go beyond pose control and give the generator the two kinds of knowledge that make up a sonographer's mental model. An anatomical prior, built from a population of subjects, guides generation where nothing has been scanned, and is refined online by every generated chunk towards the scanned subject. A 3D latent memory, designed around the cross-sectional physics of ultrasound, compounds the generated slices into a volume of the patient and reslices it at new poses, keeping revisited anatomy consistent. The fine-grained memory enters the generator at the input, while the coarse anatomy prior guides the layout across transformer blocks. Experiments on thyroid, kidney, and lumbar spine show improved visual fidelity, pose following, and anatomical consistency over pose-conditioned and memory-augmented baselines.

查看此版本解读 →查看此版本原文 ↗