跳到正文
研踪PaperTrail
← 研踪 PaperTrail

ACL Anthology · ACL 2026:acl:2026.acl-long.2038 · 记录 #1

CT-FineBench: A Diagnostic Fidelity Benchmark for Fine-Grained Evaluation of CT Report Generation

来源日期(仅到月份) 2026-07
来源记录日期 2026-07
雷达观测 2026-11-01 21:46
ACL Anthology · ACL 2026 ↗PDF ↗

摘要

The evaluation of generated reports remains a critical challenge in Computed Tomography (CT) report generation, due to the large volume of text, the diversity and complexity of findings, and the presence of fine-grained, disease-oriented attributes. Conventional evaluation metrics offer only coarse measures of lexical overlap or entity matching and fail to reflect the granular diagnostic accuracy required for clinical use. To address this gap, we propose CT-FineBench, a benchmark built from CT-RATE and Merlin to evaluate the fine-grained factual consistency of CT reports, constructed from CT-RATE and Merlin. Our benchmark is constructed through a meticulous, Question-Answering (QA) based process: first, we identify and structure key, finding-specific clinical attributes (e.g., location, size, margin). Second, we systematically transform these attributes into a QA dataset, where questions probe for specific clinical details grounded in gold-standard reports. The evaluation protocol for CT-FineBench involves using this QA dataset to query a machine-generated report and scoring the correctness of the answers. This allows for a comprehensive, interpretable, and clinically-relevant assessment, moving beyond superficial lexical overlap to pinpoint specific clinical errors. Experiments show that CT-FineBench correlates better with expert clinical assessment and is substantially more sensitive to fine-grained factual errors than prior metrics.

论文发现出处

这些页面提供论文线索,不代表同行评审或质量认证。

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

发表信息与关联版本

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

平台记录号代表本站观测到的元数据变化,不是作者修订号。来源日期仅到月份或年份时,按该月或该年首日存档。

记录 #1 · 2026-07 · 最新观测版本

CT-FineBench: A Diagnostic Fidelity Benchmark for Fine-Grained Evaluation of CT Report Generation

The evaluation of generated reports remains a critical challenge in Computed Tomography (CT) report generation, due to the large volume of text, the diversity and complexity of findings, and the presence of fine-grained, disease-oriented attributes. Conventional evaluation metrics offer only coarse measures of lexical overlap or entity matching and fail to reflect the granular diagnostic accuracy required for clinical use. To address this gap, we propose CT-FineBench, a benchmark built from CT-RATE and Merlin to evaluate the fine-grained factual consistency of CT reports, constructed from CT-RATE and Merlin. Our benchmark is constructed through a meticulous, Question-Answering (QA) based process: first, we identify and structure key, finding-specific clinical attributes (e.g., location, size, margin). Second, we systematically transform these attributes into a QA dataset, where questions probe for specific clinical details grounded in gold-standard reports. The evaluation protocol for CT-FineBench involves using this QA dataset to query a machine-generated report and scoring the correctness of the answers. This allows for a comprehensive, interpretable, and clinically-relevant assessment, moving beyond superficial lexical overlap to pinpoint specific clinical errors. Experiments show that CT-FineBench correlates better with expert clinical assessment and is substantially more sensitive to fine-grained factual errors than prior metrics.

查看此版本解读 →查看此版本原文 ↗