← 研踪 PaperTrailCVF · CVPR 2026:cvf:44a4a96ae6586001d9cd4f06b17d6de1 · 记录 #1
MedLIME: A Distribution-Aligned and Evidence-Supported Framework for Medical Saliency Explanations
来源日期(仅到年份) 2026
来源记录日期 2026
雷达观测 2026-11-05 02:57
摘要
Saliency-based explainability methods are widely used to interpret deep learning models in medical imaging, yet many existing approaches rely on white box access of models, which is not always possible due to privacy concerns. In this work, we introduce **MedLIME**, a novel, model-agnostic explanation framework designed to enhance the robustness and fidelity of saliency maps for medical imaging abnormality localization. Building upon the Local Interpretable Model-agnostic Explanations (LIME) paradigm, MedLIME integrates three key components: (1) **Generative Masking** (GM), (2) **Supervised Test-Time Adaptation** (STT) and (3) a **Evidence-based Regularization** (EBR) to improve the saliency map generation accuracy of LIME. Extensive experiments on multiple medical datasets, across three model architectures demonstrate that MedLIME consistently outperforms gradient-based and perturbation-based baselines in abnormality localization as measured by AUPRC. Our results highlight that incorporating generative reconstruction, adaptive perturbation and data-driven regularization improves the reliability and interpretability of medical imaging models.
论文发现出处
这些页面提供论文线索,不代表同行评审或质量认证。
观测到的版本
平台记录号代表本站观测到的元数据变化,不是作者修订号。来源日期仅到月份或年份时,按该月或该年首日存档。
记录 #1 · 2026 · 最新观测版本
MedLIME: A Distribution-Aligned and Evidence-Supported Framework for Medical Saliency Explanations
Saliency-based explainability methods are widely used to interpret deep learning models in medical imaging, yet many existing approaches rely on white box access of models, which is not always possible due to privacy concerns. In this work, we introduce **MedLIME**, a novel, model-agnostic explanation framework designed to enhance the robustness and fidelity of saliency maps for medical imaging abnormality localization. Building upon the Local Interpretable Model-agnostic Explanations (LIME) paradigm, MedLIME integrates three key components: (1) **Generative Masking** (GM), (2) **Supervised Test-Time Adaptation** (STT) and (3) a **Evidence-based Regularization** (EBR) to improve the saliency map generation accuracy of LIME. Extensive experiments on multiple medical datasets, across three model architectures demonstrate that MedLIME consistently outperforms gradient-based and perturbation-based baselines in abnormality localization as measured by AUPRC. Our results highlight that incorporating generative reconstruction, adaptive perturbation and data-driven regularization improves the reliability and interpretability of medical imaging models.
查看此版本解读 →查看此版本原文 ↗