跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1299新增论文
+1041其中 AI 相关
+170已有论文修订
+1新增 AI 导读

arXiv 最近完成扫描:2026-11-26 03:09 · 全站最近入库:2026-11-25 13:23各信源进度 →

统计口径与数据新鲜度

统计 2026-11-25 03:51 — 2026-11-26 03:51(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-26 03:09最近发现新增版本:2026-11-25 13:23库内论文最新更新时间:2026-11-25 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

33,231 已收录论文27,442 AI 相关10,485 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-26 03:07(北京时间)
新论文 · v1arXiv:2611.28419

Center-Aware Ordinal Learning for Prostate Cancer Grading from Histopathology Images

Mohammad Mahdi Abootorabi, Parvin Mousavi, Purang Abolmaesumi

原文摘要

Prostate cancer grading from histopathology whole-slide images (WSIs) is complicated by the ordered nature of ISUP grades, class imbalance, and center-dependent variations in staining, tissue preparation, and scanning. Most weakly supervised methods treat grade groups as independent categories and may therefore learn representations that do not transfer reliably across institutions. We propose a center-aware ordinal learning framework that combines a pretrained pathology encoder with attention-based multiple instance learning. The framework uses an Earth Mover's Distance loss to account for ordinal errors, an ordinal supervised contrastive objective to align same-grade slides across centers while separating grades according to disease severity, and curriculum learning to reduce the dominance of benign cases. We evaluate the framework on approximately 9,100 biopsy WSIs from the two-center PANDA dataset. The proposed framework achieves an accuracy of 0.842 and a quadratic weighted kappa of 0.958 on the held-out test set. Its main benefit is observed in cross-center transfer: when a linear probe is trained on Karolinska representations and evaluated on Radboud, accuracy increases from 0.643 to 0.823 and quadratic weighted kappa from 0.899 to 0.930. Performance remains stable in the reverse direction. UMAP projections further show improved mixing between centers while preserving an ordinal grade trajectory. These results suggest that combining ordinal and center-aware objectives produces more transferable slide representations for multi-center prostate cancer grading.

cs.CV · cs.AI · cs.LG

新论文 · v1arXiv:2611.09058

ProtoCouncil: Multi-Encoder Anatomical Prototypes for Prostate Cancer Detection in Micro-Ultrasound

Mohammad Mahdi Abootorabi, Nooshin Maghsoodi, Armin Saadat, Obed Dzikunu, Zhuoxin Guo, Hannes Cash, Ferdinand Luger, Adam Kinnaird 等 11 位作者

原文摘要

Purpose: Micro-ultrasound ($μ$US) is a promising modality for prostate cancer (PCa) detection, but identifying suspicious tissue depends heavily on clinical experience. Models trained on sparse, noisy core-level pathology offer little insight into their decisions and can fail under domain shift. Clinical use needs a traceable decision process and a flag for uncertain predictions. Methods: We introduce ProtoCouncil, in which three foundation encoders (MedSAM, DINOv3 and V-JEPA 2.1) learn case-based prototypes at three anatomical levels: whole gland, needle track and gland sectors. Prototypes are projected onto real training-core regions, and label-free fusion keeps every class logit as a bias plus an exact sum of prototype similarity contributions. Encoder disagreement triggers selective prediction. Results: In five-fold patient-level cross-validation (6,588 cores, 693 patients), ProtoCouncil reaches 82.9% AUROC for clinically significant PCa (csPCa, Grade Group $\geq$3), 4.3 points above the best previously published method. In zero-shot evaluation on two external cohorts, ProtoCouncil achieves higher all-cancer and csPCa AUROC than all previous methods. Nearest same-class exemplars match test-core tumor involvement better than random same-class cases. Externally, csPCa accuracy falls from 79% when encoders agree to 27% when two oppose the fused call. Abstaining on disagreement raises balanced accuracy by 7 and 15 points, while retaining 58% and 54% of the cores. Conclusion: ProtoCouncil grounds core-level predictions in exact similarity-based evidence from real, anatomically indexed training cases, which makes its reasoning interpretable. It achieves the highest csPCa AUROC across three cohorts and identifies unreliable predictions through encoder disagreement.

cs.CV · cs.AI · cs.LG