跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-09 07:12 · 全站最近入库:2026-11-08 06:02各信源进度 →

统计口径与数据新鲜度

统计 2026-11-08 09:01 — 2026-11-09 09:01(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-09 07:12最近发现新增版本:2026-11-08 06:02库内论文最新更新时间:2026-11-06 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

17,100 已收录论文14,661 AI 相关4,057 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-09 07:10(北京时间)
新论文 · v1arXiv:2610.37993

Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability

Bartosz Morawski, Samuel J. Ward, Alex Touze, Lin-Thiri Toon, Paul R. Roberts, John Paisey, Alain B. Zemkoho

原文摘要

This paper studies two non-transvenous implantable cardioverter-defibrillators (ICDs), namely the Subcutaneous ICD (S-ICD) and the Extravascular ICD (EV-ICD). Both avoid the complications of transvenous leads but are prone to oversensing, which can trigger inappropriate shocks associated with increased mortality. Oversensing risk is predicted by the ratio of T- or P-wave amplitude to R-wave amplitude (T:R, P:R), and these ratios vary over a 24-hour period. Yet S-ICD screening uses a single 10-second electrocardiogram (ECG) segment, and the EV-ICD has no formal screening protocol whatsoever. We present a 24-hour ambulatory screening framework for both devices which includes the first T:R analysis in an EV-ICD cohort and the first full evaluation of P:R prediction. We introduce AmpRatioNet, a family of 1D convolutional neural network architectures operating directly on the ECG signal, and benchmark it against the best existing approach - based on 2D phase space reconstruction images. Evaluation uses 4,605 clinician-annotated 10-second segments from 89 patients, with patient-level 10-fold cross-validation and bootstrap confidence intervals. AmpRatioNet-SE demonstrates superior performance on every metric in each setting with no device- or ratio-specific redesign. An explainability analysis against interpretable classical peak labelling algorithms shows that AmpRatioNet-SE's increase in error on oversensing-prone segments is up to 14 times smaller than theirs. Segment-level predictions are aggregated into a 24-hour timeline, extending S-ICD screening beyond 10 seconds and offering a plausible EV-ICD screening pathway pending device-level validation.

cs.LG