跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+2已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-08 10:17 · 全站最近入库:2026-11-08 06:02各信源进度 →

统计口径与数据新鲜度

统计 2026-11-07 11:37 — 2026-11-08 11:37(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-08 10:17最近发现新增版本:2026-11-08 06:02库内论文最新更新时间:2026-11-06 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

17,100 已收录论文14,661 AI 相关4,057 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-08 10:15(北京时间)
版本更新 · v3arXiv:2404.15352

TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing

Amir Arjomand, Amin Boudesh, Farnoush Bayatmakou, Kenneth B. Kent, Arash Mohammadi

原文摘要

Recent statistics indicate that approximately 1.3 billion individuals worldwide suffer from hypertension, a leading cause of premature death globally. Blood Pressure (BP) serves as a critical health indicator for accurate and timely diagnosis and/or treatment of hypertension. Traditional BP measurement methods rely on cuff-based approaches, which lack real-time, continuous, and reliable BP estimates, crucial for the timely diagnosis/treatment of hypertension. Driven by recent advancements in Artificial Intelligence (AI) and Deep Neural Networks (DNNs), there has been a surge of interest in developing data-driven and cuff-less BP estimation solutions. In this context, current literature predominantly focuses on coupling Electrocardiography (ECG) and Photoplethysmography (PPG) sensors, though this approach is constrained by reliance on multiple sensor types. An alternative, utilizing standalone PPG signals, presents challenges due to the absence of auxiliary sensors (ECG), requiring the use of morphological features while addressing motion artifacts and high-frequency noise. To address these issues, the paper introduces the TransfoRhythm framework, a Transformer-based DNN architecture built upon the recently released physiological database, MIMIC-IV. Leveraging the Multi-Head Attention (MHA) mechanism, TransfoRhythm identifies dependencies and similarities across data segments, forming a robust framework for cuff-less BP estimation solely using PPG signals. To our knowledge, this paper represents the first study to apply the MIMIC IV dataset for cuff-less BP estimation. TransfoRhythm achieves highly accurate results with a Root Mean Square Error (RMSE) of [2.21, 1.84] and a Mean Absolute Error (MAE) of [1.37, 1.06] for systolic and diastolic blood pressures, respectively.

eess.SP · cs.LG