跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1072新增论文
+845其中 AI 相关
+94已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-09 16:31 · 全站最近入库:2026-11-09 13:22各信源进度 →

统计口径与数据新鲜度

统计 2026-11-08 18:12 — 2026-11-09 18:12(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-09 16:31最近发现新增版本:2026-11-09 13:22库内论文最新更新时间:2026-11-07 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

18,172 已收录论文15,506 AI 相关4,527 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-09 16:29(北京时间)
新论文 · v1arXiv:2611.01512

Abstention Spends Its Budget on Local Label Variance More Than on Novelty: Auditing Conformal Calibration and Selective Prediction under Molecular Scaffold Shift

Arnav Srivastava, Krishna Kassetty

原文摘要

Selective prediction with split conformal calibration promises a post-hoc fix for molecular property prediction: abstain on the least reliable compounds, ideally out-of-distribution chemistry, and the retained set becomes trustworthy without retraining. We audit this recipe for a gradient-boosted fingerprint model on lipophilicity (regression) and BBBP (classification) under a Bemis-Murcko scaffold split, holding the fitted model and evaluation molecules fixed while varying only the calibration fold (18 replicates). (i) On lipophilicity, coverage depends on calibration provenance: calibrating on held-out training-scaffold molecules falls below nominal (PICP 0.841 at a 0.90 target), while novel-scaffold calibration recovers it (0.904); on BBBP, coverage stays above nominal in every regime. (ii) For split conformalized quantile regression (CQR) the conformal correction is a constant, so conformalization does not change what is abstained on. (iii) The abstention score (CQR width; effectively ensemble variance on BBBP) tracks local label variance more than chemical novelty: controlling for local label variance largely explains away the novelty association (partial Spearman 0.067 and 0.047). (iv) At a fixed assay budget, gating on interval width or ensemble variance never improves hit precision over ranking by point prediction, at the pre-specified operating point or across 20 exploratory settings; a plain novelty gate shows small, uncorrected gains at the smallest budgets. (v) In an exploratory analysis, exact conformal selection exceeds its false discovery rate target under training-scaffold calibration (0.303 at q=0.2) and is consistent with it under novel-scaffold calibration, contributing a data-driven batch size rather than a better ranking. Conformalization earns its keep through guarantees whose validity hinges on calibration provenance, not by choosing what to abstain on.

cs.LG · stat.ML