跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1878新增论文
+1565其中 AI 相关
+113已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-10 12:17 · 全站最近入库:2026-11-10 13:19各信源进度 →

统计口径与数据新鲜度

统计 2026-11-09 15:06 — 2026-11-10 15:06(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-10 12:17最近发现新增版本:2026-11-10 13:19库内论文最新更新时间:2026-11-09 16:22

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

20,050 已收录论文17,071 AI 相关5,370 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-10 12:16(北京时间)
新论文 · v1arXiv:2611.10484

Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective Study

Jiachuan Peng, Kyle Lam, Jierui Qu, Lin Li, Haining Zheng, Bang Zheng, Aniruddha Agarwal, Zaki Almallah 等 13 位作者

原文摘要

Background: Well-annotated, diverse medical imaging datasets remain a major constraint for vision-based medical AI. We evaluated Nano Banana, a general-purpose image generation and editing model, as a source of synthetic medical images for model training, subgroup augmentation, and model auditing. Methods: In this retrospective study across four imaging modalities, chest radiography, fundus photography, and CT models were trained only on synthetic images and externally validated on real-world data against real-data-trained models. Carotid ultrasound models were trained on a private Human Phenotype Project cohort (aged 40-75 years) with and without synthetic augmentation. Clinicians rated image plausibility. Evaluation used AUROC, AUPR, calibration, and decision curve analysis. Findings: Synthetic-only models achieved AUROCs of 0.877 (95% CI 0.843-0.910) for pneumonia (n=14863), 0.963 (0.948-0.975) for retinal detachment (n=1149), and 0.711 (0.600-0.823) for renal calculus (n=4122), comparable to real-data-trained models, but their calibration and net benefit were not consistently more favorable. With mixed synthetic-real training, a carotid ultrasound model produced an ordinal vascular age index that stratified 633 external subjects into subgroups differing in BMI and glucose (both p<0.01), linking vascular aging to cardiometabolic health. To stress-test shortcut learning, editing a moderate tessellated pattern into fundus photographs reduced the true-class probability for central serous chorioretinopathy from 0.996 to 0.822. Clinician-guided editing raised low-quality CT plausibility from 3.10/5 to 4.30/5. Interpretation: Synthetic data can complement real data in model training, subgroup representation, and model testing via controlled editing, but its clinical value should be assessed with calibration, decision curve analysis, and clinician review, not discrimination alone.

cs.CV · cs.AI