跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+7272新增论文
+6090其中 AI 相关
+125已有论文修订
+122新增 AI 导读

arXiv 最近完成扫描:2026-11-05 15:20 · 全站最近入库:2026-11-05 12:13各信源进度 →

统计口径与数据新鲜度

统计 2026-11-04 15:52 — 2026-11-05 15:52(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-05 15:20最近发现新增版本:2026-11-05 12:13库内论文最新更新时间:2026-11-05 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

15,949 已收录论文13,765 AI 相关3,571 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-05 15:18(北京时间)
版本更新 · v2arXiv:2607.28685

Safety, or Just Capability? A Validity Audit of Agent-Safety Benchmarks

Youting Wang, Xiao Han, Dingyan Shang, Yuan Tang, Bowen Liu

Agent-safety benchmarks measure different behaviors, and their scores get quoted interchangeably as an agent's safety. We treat four of them (R-Judge, InjecAgent, AgentHarm, AgentDojo) as measurements to be validated, running each under its official implementation and author-provided scorer on up to 22 models, with MMLU and GPQA measured by us under one protocol as a capability composite. The metric is the first problem. On any binary trace-judgment benchmark scored by $F_1$, an ``always positive'' policy attains $F_1 = 2π/(1+π)$; on R-Judge that is $0.690$, above five of the 21 models that actually discriminate. The three broad-coverage benchmarks then rank the same 18 models differently, and the trade-off behind that disagreement is a small-panel artifact: R-Judge specificity against AgentHarm safety correlates $-0.64$ at $n{=}7$ and $+0.02$ at $n{=}18$, and a quarter of random size-7 subsets reach $|ρ| \geq 0.5$ around that near-zero value. Held-out validity turns on which outcome you pick. Capability predicts task success ($ρ{=}{+}0.60$) but correlates negatively with misalignment safety ($ρ{=}{-}0.44$, $n{=}21$). On their paired $n{=}20$ panel, the corresponding contrast is $Δ{=}{-}1.00$ (95% CI $[-1.48, -0.49]$, $p<0.001$), and it survives leave-one-organization-out and organization-clustered bootstrap analyses. On an expanded 41-model panel, the misalignment correlation weakens to $-0.16$ (95% CI $[-0.54, +0.22]$) and jailbreak strengthens to $+0.34$, though neither change is significant. \mbox{AgentHarm} shows the strongest held-out association, $ρ{=}{+}0.72$ with three-template jailbreak safety after controlling capability. But both instruments score harmful compliance, so this is evidence of convergent validity rather than general safety. Naming the benchmark, metric, target behavior, and model panel is the minimum a safety claim needs.

尚无 AI 解读,展示原文摘要

cs.AI · cs.IR
arXiv ↗PDF ↗
版本更新 · v3arXiv:2511.09394

EyeAgent: An Agentic AI System for Multimodal Clinical Decision Support in Ophthalmology

Danli Shi, Xiaolan Chen, Bingjie Yan, Weiyi Zhang, Jiancheng Yang, Ruoyu Chen, Xinyuan Wu, Siyu Huang 等 26 位作者

Current medical artificial intelligence (AI) systems are often task-specific, poorly integrated, and difficult to interpret, limiting support for multimodal clinical workflows. We developed and evaluated EyeAgent for ophthalmic decision support. EyeAgent comprises three layers including 54 task-specific EyeTools, 32 clinical skills, and a modular large language model reasoning core with interchangeable backbones. A multi-level evaluation distinguished this scope from empirical system-level validation. Component-level evaluation assessed newly developed models on held-out splits of datasets totaling 871,862 samples. System-level evaluation included illustrative cases of workflow breadth, a 200-case expert-rating study of output quality, and an exploratory multicenter reader study comparing unassisted and EyeAgent-assisted performance among 27 ophthalmologists from 11 centers. Skill-level and backbone ablations further assessed orchestration and robustness. In illustrative cases, EyeAgent showed task-specific advantages over GPT-5.5 in lesion quantitation, cross-modality synthesis, and uncertainty-aware reporting. In the expert-rating study, EyeAgent achieved an F1 score of 0.84 for skill selection, with 82.7%-92.0% of outputs rated acceptable or better across six clinical dimensions. In the exploratory multicenter reader study, diagnostic accuracy increased from 72.8% unassisted to 91.9% assisted (difference, 19.1 percentage points (pp); 95% CI, 13.6-24.7; Holm-adjusted P<0.001). Report completeness increased from 55.8% to 75.6% (difference, 19.8 pp; 95% CI, 14.8-24.7; Holm-adjusted P<0.001). Across the evaluated settings, EyeAgent supported interpretable, evidence-guided reasoning and showed potential for human-AI collaboration. Broader real-world effectiveness and generalizability require prospective and cross-population validation.

尚无 AI 解读,展示原文摘要

cs.HC
arXiv ↗PDF ↗