跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+2471新增论文
+2025其中 AI 相关
+163已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-10 18:29 · 全站最近入库:2026-11-10 15:22各信源进度 →

统计口径与数据新鲜度

统计 2026-11-09 18:35 — 2026-11-10 18:35(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-10 18:29最近发现新增版本:2026-11-10 15:22库内论文最新更新时间:2026-11-10 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

20,643 已收录论文17,531 AI 相关5,643 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-10 18:28(北京时间)
新论文 · v1arXiv:2611.10062

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi

原文摘要

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

cs.CV