跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-09 07:12 · 全站最近入库:2026-11-08 06:02各信源进度 →

统计口径与数据新鲜度

统计 2026-11-08 07:14 — 2026-11-09 07:14(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-09 07:12最近发现新增版本:2026-11-08 06:02库内论文最新更新时间:2026-11-06 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

17,100 已收录论文14,661 AI 相关4,057 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-09 07:10(北京时间)
新论文 · v1arXiv:2611.07784

EnergyBench: a live, gate-aligned benchmark of day-ahead forecasts for European power markets

Evgenii Genov, Ander Martinez Alonso, Christoph Bergmeir

原文摘要

Energy forecasting models are usually compared on backtests and fixed public datasets. Backtests can use data that did not yet exist when the forecast would have been made, and a fixed test set, reused across studies and possibly contained in the pretraining data of foundation models, invites overfitting to the benchmark. EnergyBench evaluates every entry live instead. Each day at 11:30 CET/CEST, thirty minutes before the day-ahead (SDAC) gate closes, every model forecasts the next day's price, wind and solar generation and load on the 15-minute grid for six bidding zones (BE, NL, FR, DE-LU, DK1, DK2). Unlike existing live benchmarks, EnergyBench runs the models itself, on one information set that it freezes at the cut-off and publishes, including three numerical weather prediction models, so that foundation models can be compared with and without the same weather covariates under the actual market deadline. Errors are pooled per series against a seasonal-naive baseline, and models are ranked by a Bradley-Terry rating on the Elo scale with a day-bootstrap interval. The field spans baselines, linear and gradient-boosted models on the frozen weather, eighteen time-series foundation models from eleven families, ensembles, and the grid operators' own forecasts. Over the first thirty-two live days, the covariates reduced the error of each of the ten foundation models run with and without them by 37-51% on matched races (64-73% on wind, 48-61% on solar). Used zero-shot, these models match or outperform a LightGBM model trained on the same covariates. Model size, from 3M to 331M parameters, has a much smaller effect, and median ensembles of the covariate models rank highest. The grid operators' pre-gate forecasts remain ahead on wind and solar, where the best single foundation models have 16-22% more error; on load the gap is 4-6%, within the intervals.

cs.LG · eess.SY