跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+1已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-07 19:34 · 全站最近入库:2026-11-07 17:43各信源进度 →

统计口径与数据新鲜度

统计 2026-11-06 19:35 — 2026-11-07 19:35(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-07 19:34最近发现新增版本:2026-11-07 17:43库内论文最新更新时间:2026-11-06 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

17,100 已收录论文14,661 AI 相关4,056 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-07 19:30(北京时间)
新论文 · v1arXiv:2610.35271

Low-rank MERA Decomposition of 3D OCT Image Volume for Compression, Denoising, Feature Extraction and Diagnosis of Retinal Diseases

Ivica Kopriva, Fei Shi, Marija Štanfel, Qin Peng, Jianhao Bao, Gaowei Li, Xinjian Chen

原文摘要

Optical coherence tomography (OCT) is a non-invasive imaging modality used for visualization of retinal tissue. However, OCT volumes are affected by speckle noise, which degrades image contrast and obscures fine structural details. Furthermore, modern clinical practice requires large field-of-view, high-resolution OCT volumes, whose storage and transmission are demanding for archiving and teleophthalmology applications. To address aforementioned challenges, we propose a low-rank multi-scale entanglement renormalization ansatz (MERA) tensor network approximation of 3D OCT image volume, where the image volume is represented as contractions of a top core factor encoding global features and multiple interacting low-rank orthogonal or semi-orthogonal factors modeling inter- and intra-B scan correlations. This representation jointly enables compression, denoising, and feature extraction. Unlike deep learning approaches, the proposed approach is training-free and processes each OCT volume independently. We evaluate the proposed framework on OCT image volumes acquired by two different scanners and demonstrate improved visual quality and reduced retinal layer segmentation errors in comparison with several competing methods. We also extract MERA features from two clinical OCT volume datasets. They are subsequently classified using a Grassmann-manifold nearest-subspace classifier. With the subspace dimension as its only hyperparameter, the classifier is theoretically shown to be robust in small-sample clinical scenario. We demonstrate competitive accuracy of classification of retinal diseases in these small-sample settings, where deep learning methods are often limited by the scarcity of labeled data. The proposed structure-aware model-driven representation learning for high-dimensional data under limited supervision provides good generalization performance while maintaining high interpretability.

cs.CV