跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+6108新增论文
+5221其中 AI 相关
+108已有论文修订
+122新增 AI 导读

arXiv 最近完成扫描:2026-11-05 06:01 · 全站最近入库:2026-11-05 04:38各信源进度 →

统计口径与数据新鲜度

统计 2026-11-04 06:07 — 2026-11-05 06:07(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-05 06:01最近发现新增版本:2026-11-05 04:38库内论文最新更新时间:2026-11-04 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

14,785 已收录论文12,896 AI 相关3,088 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-05 05:58(北京时间)
新论文 · v1arXiv:2611.05206

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang, Yiwen Luo, Yixuan Chen, Graham Treece 等 10 位作者

\textit{Objective:} Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. \textit{Methods:} We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. \textit{Results:} On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. \textit{Conclusion:} Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. \textit{Significance:} UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

尚无 AI 解读,展示原文摘要

cs.CV
arXiv ↗PDF ↗