跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

采集已暂停
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:等待完成 · 全站最近入库:2026-11-02 00:39各信源进度 →

统计口径与数据新鲜度

统计 2026-11-03 16:24 — 2026-11-04 16:24(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:尚未完成最近发现新增版本:2026-11-02 00:39库内论文最新更新时间:2026-10-30 01:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

8,677 已收录论文7,675 AI 相关1,866 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。

找到 1 篇论文 · 按版本更新时间排序等待首次采集
新论文 · v1arXiv:2610.37083

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan, Chang-Fu Su, Eng-Che Huang, Yuan-Ren Cheng

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

尚无 AI 解读,展示原文摘要

cs.SD
arXiv ↗PDF ↗