跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+7272新增论文
+6090其中 AI 相关
+125已有论文修订
+122新增 AI 导读

arXiv 最近完成扫描:2026-11-05 18:27 · 全站最近入库:2026-11-05 12:13各信源进度 →

统计口径与数据新鲜度

统计 2026-11-04 18:33 — 2026-11-05 18:33(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-05 18:27最近发现新增版本:2026-11-05 12:13库内论文最新更新时间:2026-11-05 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

15,949 已收录论文13,765 AI 相关3,571 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 3 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-05 18:25(北京时间)
新论文 · v1arXiv:2611.05936

LumiTac: Compact, High-Rate Six-Axis Optical Tactile Sensing for Human-Robot Interaction

Hao Wu, Haotian Guo, Yu Feng, Yutong Wang, Jianshu Zhou

Integrating six-axis tactile feedback into robotic interfaces requires compact sensors with accurate load measurement and rapid online reconstruction. This paper presents LumiTac, a low-profile, camera-free optoelectronic tactile sensor combining spatially distributed illumination with spectral encoding. Five photoemitters and five RGBW photoreceivers are mounted on opposing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical channels. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small forces, and transient response, respectively. Robotic demonstrations further validated its applicability to tactile-guided manipulation and physical human-robot interaction. This study paves the way for compact, high-rate optical tactile sensing in robotic manipulation and human-robot interaction.

尚无 AI 解读,展示原文摘要

cs.RO
arXiv ↗PDF ↗
版本更新 · v2arXiv:2611.01609

MagPillar: A Soft Magnetopillar Array Tactile Sensor for Robotic Surface Perception

Haotian Guo, Yu Feng, Hao Wu, Jiazhi Tang, Ningbin Zhang, Jianshu Zhou

Robotic surface exploration benefits from tactile interfaces that accommodate contact and capture variations in surface characteristics. Herein, we report MagPillar, a tactile sensor inspired by spider tactile hairs that combines a magnetic pillar array with three-axis Hall sensing. A full-array mechanical and magnetic-field model characterizes how pillar deformation affects the superposed fields measured across the array, providing a physical basis for interpreting its contact responses. The compliant pillar architecture translates contact with surface textures and geometric features into distinct magnetic response patterns. Then, in robotic surface perception experiments, spectral features and logistic regression distinguish six material surfaces with an offline accuracy of 99.34% under within-session temporally blocked cross-validation. Continuous scans over periodic protrusions produce amplitude and peak-spacing variations consistent with changes in surface geometry. These findings connect compliant contact mechanics with distributed magnetic sensing, paving a new path for material recognition and qualitative surface-profile perception.

尚无 AI 解读,展示原文摘要

cs.RO
arXiv ↗PDF ↗
版本更新 · v3arXiv:2610.09536

MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping Feedback

Yu Feng, Hao Wu, Haotian Guo, Haoming Liu, William Su, Jingxiang Guo, Jiankun Li, Masayoshi Tomizuka 等 10 位作者

Robotic grasping and surface exploration benefit from simultaneous measurement of normal and tangential forces and from surface information obtained through contact. Here, we present a compact magnetociliary tactile sensor (MagCilia) that combines a flexible magnetic-cilia structure with a Hall sensor for 3D force sensing. Quasi-static finite element analysis is used to investigate structural deformation and magnetic responses under multidirectional loading. To reconstruct forces from the coupled magnetic channels, we propose causal history fusion regression (CHFR), which combines current magnetic-field measurements with their recent changes. Five-fold cross-validation grouped by calibration record yields root-mean-square errors of 0.40, 0.57, and 0.69 N for Fx, Fy, and Fz, respectively, with corresponding coefficients of determination of 0.93, 0.90, and 0.92. Robotic experiments demonstrate tangential-force-guided gripper adjustment and multi-axis load monitoring under external perturbations. Frequency-domain features of the reconstructed forces distinguish six surface categories with 99.39% accuracy in three-fold cross-validation grouped by acquisition session. An online robotic demonstration additionally identifies all six tested surfaces. These results demonstrate 3D force reconstruction, grasping feedback, and surface recognition using a single compact tactile unit.

尚无 AI 解读,展示原文摘要

cs.RO
arXiv ↗PDF ↗