跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1087新增论文
+804其中 AI 相关
+107已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-14 11:06 · 全站最近入库:2026-11-13 20:44各信源进度 →

统计口径与数据新鲜度

统计 2026-11-13 11:24 — 2026-11-14 11:24(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-14 11:06最近发现新增版本:2026-11-13 20:44库内论文最新更新时间:2026-11-13 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,348 已收录论文19,580 AI 相关6,727 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-14 11:04(北京时间)
版本更新 · v2arXiv:2610.21895

SurgStreamer: proactive, request-driven monitoring of surgical video streams with structured state and a reusable reasoning layer

Bowen Xiang, Jon S. Heiselman

原文摘要

Surgical teams could benefit from assistants that watch the video for requested events, such as "tell me when the clip applier appears during Calot triangle dissection", and answer questions about what has already happened. We formalise this task as request-driven event detection with exact semantics and causal alert decisions, and present SurgStreamer. It separates procedure-specific perception, which maps the 1-FPS stream to a structured state over tools, actions and phases, from procedure-agnostic reasoning, which evaluates a formal monitoring condition over this state and an event memory, either with exact rules or with a small controller that addresses entities through pointers rather than names. We evaluate this monitoring core with gold conditions. On a pre-registered, sealed test set of 12 laparoscopic cholecystectomies, SurgStreamer reached a macro event-F1 of 0.598 over full procedures. On identical 75-s windows with only the window available to every method, it scored 0.677. The tested configurations of the streaming vision-language model OneStreamer-4B, including ones fine-tuned on SurgStreamer's state or on video with an adapted vision encoder, scored at most 0.540 (Holm-adjusted p <= 0.012). At three external centres, re-training only perception raised performance on held-out procedures from 0.239 to 0.470. On a new procedure, pituitary surgery, controller weights trained on cholecystectomy matched an in-domain controller on oracle state (0.947 vs 0.938). On predicted state they missed the pre-registered non-inferiority margin (-0.024 [-0.040, -0.008]) unless the alert thresholds were re-calibrated. The results support separating perception from reasoning and point to perception under distribution shift as the main limitation.

cs.CV