AI 速览:作者提出一种乐高兼容的气动人工肌肉模块及配套 MuJoCo 仿真器,用于快速搭建和探索可重构肌肉骨骼机器人。
Musculoskeletal robots combine compliant actuators with articulated skeletons, but exploring alternative configurations often requires repeated fabrication. We present MUSBRIC, a modular hardware platform and accompanying MuJoCo-based simulator for reconfigurable musculoskeletal robots. LEGO-compatible endcaps turn fiber-reinforced extensile pneumatic artificial muscles into reusable, plug-and-play muscle bricks that connect directly to standard LEGO components. Experimentally identified actuator behavior supports corresponding musculoskeletal simulations. An elbow-joint prototype validates load-dependent flexion and extension, showing that pulley-guided routing enables reversible motion and a mechanical stop stabilizes the straight posture. A robotic hand demonstrates compliant grasping and multi-joint construction. Matched hardware and simulation sweeps across 15 leg configurations demonstrate systematic exploration of attachment geometry, while a quadruped assembled from four legs demonstrates walking. Together, these demonstrations span mechanism analysis, configuration exploration, and functional robot construction within a single reconfigurable system. The hardware designs and simulation code will be released as open source soon to facilitate reproduction and further development.
Small-molecule identification from tandem mass spectrometry (MS/MS) may require complementary measurements. Herein, we propose a structure-informed deep Q-network (SI-DQN) that uses existing MS/MS evidence to decide whether further characterization is needed, which measurement to request, and when to stop. The policy combines spectral representations and candidate rankings with score-weighted descriptors of the candidates' chemical features and structural differences. The policy was evaluated on 79,462 held-out samples with simulated MS/MS, infrared (IR), and nuclear magnetic resonance (NMR) spectra from the Multimodal Spectroscopic Dataset. Evaluation used fixed hard candidate sets containing the correct structure and equal normalized acquisition costs. Averaged across three training runs, SI-DQN increased Top-1 accuracy from 80.10% to 93.78% for positive-ion MS/MS starts and from 70.44% to 93.31% for negative-ion starts. The corresponding mean additional measurement counts were only 0.227 and 0.340 per sample, respectively. Complete acquisition achieved 97.72% accuracy with four additions, whereas SI-DQN reduced the additional measurement count by 94.3% and 91.5%. Relative to a rule-based policy, SI-DQN reduced the composite loss combining terminal ranking error and acquisition cost by 19.3% and 25.5%. Adding structural information to DQN further improved accuracy while reducing requests across all three training runs. At comparable ranking uncertainty, SI-DQN increased request rates relative to DQN more strongly in groups with high structural disagreement, where larger reductions in composite loss were also observed. Together, these results support using the ambiguity among candidate structures after MS/MS analysis to guide further characterization, providing a quantitative basis for balancing identification performance against subsequent measurement effort.
Differences in musculoskeletal morphology challenge policy reuse across individual models. Here we present MyoAcross, a framework that combines individual musculoskeletal model construction, morphology-conditioned policy learning and virtual model augmentation to enable muscle-driven reference-motion tracking without individual fine-tuning. Across 31 held-out individual models, MyoAcross achieves 99.24% completion and reduces tracking error by 22.60% relative to an unconditioned multilayer perceptron. Policy reuse extends to models of 22 held-out individuals constructed from single-image shape estimates, measured height and body mass, and, with asymmetry augmentation, to models with unilateral lower-limb shortening. Comparisons with measurements from 120 additional individuals show agreement in vertical ground reaction force waveforms and channel-dependent agreement between simulated muscle activations and electromyography. These results establish a common control framework for comparative simulations of movement across individual musculoskeletal models.
A numerical claim generated by a financial analyst agent can match a number in a company filing but refer to the wrong entity, concept, period, unit or scope. A check based on reference answers can mark such an answer as wrong but does not explain why it fails. In this paper, we present NumTrace, a new benchmark that audits the provenance of each numerical claim made by financial analyst agents: its source and financial semantics. NumTrace currently has 540 questions over 2,163 SEC EDGAR documents. To the best of our knowledge, it is the first numerical benchmark about who holds a company's shares (Form 13F) and what its executives are owed (Item 402(i)). On a frozen snapshot of these documents, we build the reference answers according to accounting rules. NumTrace then gives each claim three separate verdicts: value, binding and support. By retaining separate value and binding verdicts, NumTrace detects right number, wrong account (RNWA) errors: a claim has an RNWA error when it passes the value check but fails the binding check. The RNWA rate quantifies the gap between value-only and joint value-and-binding pass rates. Finally, we audit three agents, Claude Opus 5.5, GPT-6 Astra and DeepSeek-V4.1-Flash. RNWA errors make up 67.5-81.8% of each agent's failing claims. In particular, on 13F co-filing group questions, about 91% of claims pass the value check, but fewer than half pass the binding check.