跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+7272新增论文
+6090其中 AI 相关
+125已有论文修订
+122新增 AI 导读

arXiv 最近完成扫描:2026-11-05 12:14 · 全站最近入库:2026-11-05 12:13各信源进度 →

统计口径与数据新鲜度

统计 2026-11-04 13:25 — 2026-11-05 13:25(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-05 12:14最近发现新增版本:2026-11-05 12:13库内论文最新更新时间:2026-11-05 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

15,949 已收录论文13,765 AI 相关3,571 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-05 12:12(北京时间)
新论文 · v1arXiv:2610.35246

NOMAD-EEG: Native Omni-Montage Adaptive Diffusion

Abdulkader Helwan, Khadidja Henni, Lina Abou-Abbas

Purpose. Electroencephalography (EEG) montages, channel counts and recording lengths vary widely, but most EEG foundation models are bound to the channel set and input length they were trained on. We aimed to build a generative EEG foundation model independent of the number, identity and order of electrodes and of the input length. Methods. NOMAD-EEG is a 12.0 M-parameter diffusion model that alternates state-space layers along time, without patches, with attention across electrodes identified only by their 3D scalp position. It was pre-trained on 147 h of unlabelled EEG from a single corpus and evaluated with frozen linear probes on ten datasets with 1 to 64 electrodes against seven foundation models run under one protocol, and on two unseen populations. Results. Despite its small size (12.0 M parameters against 69 M for REVE) and single pre- training corpus, NOMAD-EEG outperformed all seven foundation models on EEGMMIDB mo- tor imagery (balanced accuracy 0.442), Siena seizure detection (macro F1 0.622) and Bonn seizure detection (AUROC 0.999), had the highest accuracy of the seven compared models on TUEP epilepsy diagnosis (0.640) and, after fine-tuning, the highest \k{appa} (0.635) and weighted F1 (0.814) on TUEV event classification. It was the best of five models on P300 detection in autism with an unseen eight-electrode montage (AUROC 0.718). With only 5 of 19 electrodes, its mean AUROC fell only from 0.942 to 0.891. Conclusion. Identifying electrodes by position and modelling time without patches let one small model, pre-trained on one corpus, outperform much larger EEG foundation models on seizure detection, epileptiform event classification, epilepsy diagnosis and motor imagery.

尚无 AI 解读,展示原文摘要

cs.LG · eess.SP
arXiv ↗PDF ↗