跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+4369新增论文
+3911其中 AI 相关
+96已有论文修订
+115新增 AI 导读

arXiv 最近完成扫描:2026-11-05 23:43 · 全站最近入库:2026-11-05 12:13各信源进度 →

统计口径与数据新鲜度

统计 2026-11-04 23:43 — 2026-11-05 23:43(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-05 23:43最近发现新增版本:2026-11-05 12:13库内论文最新更新时间:2026-11-05 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

15,949 已收录论文13,765 AI 相关3,571 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-05 23:41(北京时间)
新论文 · v1arXiv:2611.05341

权重空间编程用于审计临床决策网络

Weight-space programming for auditing clinical decision networks

Humza Nusrat, Omar Nusrat

AI 速览:作者报告前沿语言模型仅凭临床协议和网络权重即可盲审并修复小型放疗决策网络中的部分植入缺陷,但尚不能证明网络正确。

Machine learning models in radiotherapy are commissioned by testing them on cases with known answers, which may not reveal a shortcut that the test cases share with the training data. Frontier language models have recently been reported to read and write the raw weights of small neural networks, an ability called weight-space programming. The purpose of this study was to determine whether such a model, given only a clinical protocol and a network's weights, can audit and repair the network. Networks with 433 to 4,801 parameters were trained to screen head-and-neck planning requests against four rules. Flaws were planted through the training data: confounds that hid each rule, a 3 Gy shift in the cord threshold, and a hidden trigger. Claude Opus 5.5 audited each network blind, without tools, data or code execution, and every claim and repair was tested on about 420,000 requests. The language model named the broken rule in 16 of 18 flawed networks (95% CI 67% to 97%), including all 15 with a confound or a threshold shift. It repaired each of the 16 by changing a median of 3 parameters. Fine-tuning on protocol-labeled requests also repaired every network, but changed nearly every parameter. Each confound and shift it found was visible in single units, and a simple statistic chosen for each flaw type found the same flaws. It cleared 2 of 5 healthy networks without being forced and found 1 of 3 triggers. Testing against the protocol detected every flaw, and black-box testing found the confounds and the shift faster. The results indicate that, in small networks, weight-space programming can locate and repair flaws that silence an input or shift a threshold, but cannot yet certify that a network is correct.

physics.med-ph · cs.AI
arXiv ↗PDF ↗
新论文 · v1arXiv:2611.05340

MedPhysBench:评估语言模型在医学物理计算与错误检测上的基准

MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection

Omar Nusrat

AI 速览:作者构建了一个覆盖放疗、诊断影像、核医学与辐射防护的医学物理计算与查错基准,并报告了12个语言模型在留出测试集上的表现。

Medical physicists turn a prescription into a delivered dose and check one another's calculations, because one error in a beam calibration or a monitor-unit (MU) calculation can affect every patient treated with it. MedPhysBench has ten seeded generators of calculation items in radiation therapy, diagnostic imaging, nuclear medicine and radiation protection, up to clinical tasks such as a TG-51 calibration worksheet. Reference answers come from code implementing the governing protocols, and a grader converts units and applies tolerance bands. From the same inputs, separate checking items test error detection, showing a colleague's worksheet or only the colleague's result, half correct and half with one planted error. On a held-out test split of 1,200 items (half for two models), 12 models scored 33.3 to 100.0% on calculation. Of the nine answers graded incorrect for the four best (99.3-100.0%), five contained model errors and four followed NCRP Report 151 on points our items misstate or leave open. Below them, most models did worst on level-3 clinical tasks, and Claude Sonnet 5.5 omitted the inverse-square correction in 19 of 20 isocentric MU items. Five models detected at least 96.7% of mostly large planted errors with at most 4% false alarms; for four of the other seven, checking only the result raised false alarms significantly. In an exploratory targeted test with 20 public cases of an omitted inverse-square correction, the three best models tested caught it in every worksheet, and three weaker models accepted 16 to 18 of 20 planted worksheets, one of them while applying the correction in most of its own calculations. Claude Opus 5.5 accepted 6 of 20 wrong results, although it applied the correction in all 20 of its own. We report the effect of two problems in our shielding items, found after the runs, and release the code, per-item outcomes and targeted-test responses.

physics.med-ph · cs.AI · cs.CL
arXiv ↗PDF ↗