跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

采集已暂停
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:等待完成 · 全站最近入库:2026-11-02 00:39各信源进度 →

统计口径与数据新鲜度

统计 2026-11-03 07:31 — 2026-11-04 07:31(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:尚未完成最近发现新增版本:2026-11-02 00:39库内论文最新更新时间:2026-10-30 01:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

8,677 已收录论文7,675 AI 相关1,866 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。

找到 1 篇论文 · 按版本更新时间排序等待首次采集
新论文 · v1arXiv:2610.40478

基于CT-to-MRI合成与保形预测的无需MRI的PET精确定量及可靠性评估

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction

Jungwoo Seo, Seung Yun Choi, Kun Ho Lee, Seun Jeon, Byoung Seok Ye, Jiook Cha

AI 速览:作者提出将切片一致的Brownian Bridge扩散模型用于CT-to-MRI合成,并结合保形预测,实现无需个体MRI的淀粉样蛋白PET SUVR定量及其可靠性区间评估。

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On $^{11}$C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE $0.016 \pm 0.015$, Pearson $r = 0.9987$) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.

cs.CV
arXiv ↗PDF ↗