跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1072新增论文
+845其中 AI 相关
+94已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-09 15:29 · 全站最近入库:2026-11-09 13:22各信源进度 →

统计口径与数据新鲜度

统计 2026-11-08 16:28 — 2026-11-09 16:28(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-09 15:29最近发现新增版本:2026-11-09 13:22库内论文最新更新时间:2026-11-07 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

18,172 已收录论文15,506 AI 相关4,527 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-09 15:27(北京时间)
新论文 · v1arXiv:2611.08993

When2What: A Timing-Conditioned Framework for Long-Horizon Forecasting of Continuous Cardiovascular Waveforms

Chaoqi Zhang, Shujie Yan, Zhao Zhang, Yanhua Sun, Yu Wang, Li Li, Lingzhong Meng, Xiaoyi Chen 等 9 位作者

原文摘要

Long-horizon forecasting of quasi-periodic cardiovascular waveforms, such as the electrocardiogram (ECG), arterial blood pressure (ABP), and photoplethysmogram (PPG), requires predicting both when future cardiac events will occur (beat timing) and what the local structural pattern looks like around each event (beat morphology). However, standard sequence forecasters trained with pointwise mean squared error (MSE) average across uncertain future heartbeat phases, flattening sharp R peaks and pulse upstrokes into featureless baselines. Our analysis of intraoperative ECG reveals a clear temporal asymmetry: beat-time predictability from history decays within seconds due to stochastic heart-rate variability, whereas local beat morphology aligned at true beat times remains stable over several minutes. Guided by this insight, we introduce When2What, a timing-conditioned framework comprising three stages: Predict, Commit, and Generate. Given a 120-s history, When2What predicts a dense 60-s timing map, selects and sharpens discrete beat events into unit-height Gaussian impulses, and conditions a neural waveform generator on both these committed events and the observed history. Across intraoperative ECG, When2What substantially outperforms existing time-series and physiological forecasters, achieving a near-term waveform event skill of 0.644 and reproducing 95.62% of its predicted heartbeats in the generated waveform where direct long-horizon forecasters collapse into flat baselines. Furthermore, When2What transfers zero-shot to external hospital and atrial fibrillation cohorts, extends effectively to ABP and PPG pulse waveforms, and is supported by ablations and synthetic analyses that establish explicit timing conditioning as an effective paradigm for quasi-periodic long-horizon waveform forecasting.

cs.LG