跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1164新增论文
+869其中 AI 相关
+88已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-06 05:59 · 全站最近入库:2026-11-05 12:13各信源进度 →

统计口径与数据新鲜度

统计 2026-11-05 06:02 — 2026-11-06 06:02(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-06 05:59最近发现新增版本:2026-11-05 12:13库内论文最新更新时间:2026-11-05 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

15,949 已收录论文13,765 AI 相关3,571 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-06 05:57(北京时间)
新论文 · v1arXiv:2611.01723

A sensor-driven physics-informed neural network for real-time occupant-centric space heating control

Yunfei Bai, Chenghao Li, Sunku Prasad Jenne, Hao Wang, Sizhe Zhang, Jihong Wang

Conventional space heating systems typically rely on single or sparse fixed-point temperature measurements, overlooking non-uniform indoor temperature distributions, transient thermal dynamics, and occupant-specific comfort requirements. This study explores an occupant-centric control strategy that aims to maintain the desired temperature around the occupant location. Spatially and temporally varying temperature fields, together with occupant mobility, make real-time local temperature estimation challenging. To address this challenge, we propose a control-oriented Physics-Informed Neural Network (PINN) model for indoor temperature-field prediction. Conventional PINNs rely on explicit time inputs and assume consistent temporal patterns across samples, which limits adaptability under variable initial conditions and heating sequences. The proposed model infers temporal dynamics implicitly from spatial coordinates and limited sensor measurements, improving robustness to changes in initial conditions and external disturbances. The method was validated across nine horizontal sensing planes in three controlled room-scale configurations. Against a validated COMSOL Multiphysics simulation, the PINN predicted the evaluated temperature fields with a maximum relative error below 1.85% across validation cases. These predictions supported an occupant-centric space heating control scheme. Compared with COMSOL-based offline control, the PINN-based system achieved an average prediction error of around 0.67%, and its rapid inference supports real-time occupant-centric control implementation. This work represents a move away from reliance on fixed-point temperature measurements in space heating control to an occupant-centric control strategy informed by real-time environmental feedback.

尚无 AI 解读,展示原文摘要

cs.LG · eess.SY
arXiv ↗PDF ↗