跳到正文
研踪PaperTrail

YOUR RESEARCH, IN SIGHT

让下一篇重要论文,不再错过。

覆盖计算机全学科,以 AI 为快捷入口。关注方向、作者和关键词,把发现变成持续的研究积累。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1072新增论文
+845其中 AI 相关
+94已有论文修订
+100新增 AI 导读

arXiv 最近完成扫描:2026-11-09 22:47 · 全站最近入库:2026-11-09 13:22各信源进度 →

统计口径与数据新鲜度

统计 2026-11-08 23:22 — 2026-11-09 23:22(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-09 22:47最近发现新增版本:2026-11-09 13:22库内论文最新更新时间:2026-11-07 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

18,172 已收录论文15,506 AI 相关4,527 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-09 22:43(北京时间)
版本更新 · v2arXiv:2609.03118

Efficient Co-simulator Integration with Application to Smart Grids

Talha Ibn Aziz, Jihoon Og, Ioanis Nikolaidis, Omid Ardakanian

原文摘要

The evolution of the electric power grid towards a ``smart grid'' is an example of an emerging large-scale cyber-physical system. To study the potential of cyberattacks or other sources of extreme events, high-fidelity co-simulation is one of the few realistic strategies. In this work, we demonstrate a practical and high-performance co-simulation strategy for smart grids, which provides lessons about co-simulation integration that can be carried over to other cyber-physical systems. Specifically, we present a co-simulation platform based on the Mosaik framework that integrates several federates including OpenDSS for power flow, a refined NS-3 for communication networks, and custom Python-based simulators for on-load tap changer control, distributed state estimation, and data collection. We compare synchronization strategies -- exhaustive lock-step time advancement versus an optimized event-driven approach that exploits lower-bound time stamps (LBTS) and next-event prediction -- and introduce targeted refinements to NS-3 event handling and relevance filtering of internal events. Performance is evaluated on two standard IEEE benchmark systems: the 13-node test feeder with tap-changer voltage regulation and a large-scale 33-bus system augmented with 32 European low-voltage feeders (1,793 nodes total) performing distributed state estimation with thousands of phasors and smart meters. Experimental results demonstrate that the refined event-based synchronization that uses LBTS-based NS-3 event filtering reduces execution time by up to 50\% over non-filtered LBTS, and more than 4$\times$ in the tap control scenario compared to naïve lock-step methods, while strictly preserving temporal correctness and simulation accuracy.

cs.NI