跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1202新增论文
+980其中 AI 相关
+155已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-26 17:41 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-26 02:23 — 2026-11-27 02:23(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-26 17:41最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-26 17:39(北京时间)
新论文 · v1arXiv:2611.34618

Automated Batch-Variable Selection for ComBat-Based Radiomic Harmonization

Jose Lozano-Montoya, Gemma Urbanos, Carmen Prieto-de-la-Lastra, Emilio Soria-Olivas, Ana Jimenez-Pastor

原文摘要

ComBat harmonizes multicentre radiomic features, but batch variables are usually chosen manually, without a standardized criterion across image acquisition parameters. We propose ParsiComBat, which selects acquisition parameters for ComBat, balancing batch-effect removal against feature-structure preservation and abstaining when technical variation is negligible. ParsiComBat ranks candidate acquisition parameters by batch effect, filters redundancy, and scores sequential ComBat corrections. We evaluated it in three experiments: in simulations, testing whether it recovered a known batch variable and abstained without one; in CT (NSCLC-Radiomics) and MRI (MAMA-MIA) cohorts, comparing batch-effect removal against manufacturer (manual), every feasible parameter (greedy) and AutoCombat; and in clinical prediction, internally and externally. In simulations, ParsiComBat identified the true batch variable in 92.9% of positive trials and abstained in 99.2% of null controls. In CT, correcting for reconstruction kernel reduced mean k-nearest neighbour batch-effect test from 0.276 to 0.032, almost matching greedy correction of six variables. In MRI, correcting for slice thickness and manufacturer reduced it from 0.680 to 0.325, slightly more than manual selection but less than greedy correction of seven variables. Removing technical variation did not improve clinical discrimination: no strategy, including raw features, differed significantly from ParsiComBat in area under the curve. ParsiComBat provides a data-driven framework that removes technical batch effects using minimal acquisition parameters, preserving feature structure and clinical discrimination. It selects variables verifiable against the acquisition protocol and abstains when no correction is needed, supporting transparent, reproducible multicentre radiomics.

cs.LG

版本更新 · v2arXiv:2611.02197

Conditional Diffusion-Based Generation of T2-Weighted Prostate MRI for Clinically Significant Prostate Cancer Classification

Xavier Rafael-Palou, Alejandro Vergara-Richart, Ignacio Iborra Roncales, Carmen Prieto-de-la-Lastra, Andreu Antolin-Redondo, Juan Morote, Ana Jimenez-Pastor

原文摘要

Scarce and unrepresentative training data limit the performance of prostate MRI prediction models. Synthetic T2-weighted (T2W) MRI may augment training data containing clinically significant prostate cancer (csPCa) and transition zone (TZ) lesions. In this retrospective, single-center, ethics-committee-approved study, we developed a conditional generative model for T2W prostate MRI extending MAISI-v2 with csPCa class, zonal, and lesion-mask-guided conditioning, incorporating a relative advantage weighted loss fine-tuned on 1,303 patients (1,654 lesions). Fidelity was assessed by incremental ablation, and downstream utility was evaluated with T2W-based csPCa classifiers across five simulated training-data scenarios, each testing 18 synthetic-data configurations. The proposed model reduced Fréchet inception distance (FID) from 13.28 (pretrained MAISI-v2) to $2.04 \pm 0.06$ internally (PI-CAI: $3.83 \pm 0.51$). Synthetic augmentation significantly increased AUC in all five scenarios (+0.027 to +0.088; adjusted $p = 0.016$--$0.043$), though cross-institutional augmentation of PI-CAI yielded a non-significant gain (+0.013; $p = 0.397$). Overall, our model improved T2W MRI fidelity, and synthetic images improved csPCa classification under simulated data constraints, although benefit did not transfer significantly across institutions.

cs.CV