跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1085新增论文
+884其中 AI 相关
+130已有论文修订
+59新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-18 19:45各信源进度 →

统计口径与数据新鲜度

统计 2026-11-17 20:24 — 2026-11-18 20:24(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-18 19:45库内论文最新更新时间:2026-11-18 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

26,870 已收录论文22,374 AI 相关8,156 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
新论文 · v1arXiv:2611.20114

A plug-in energy-balance freezing module for transformer frost nowcasting without leaf-sensor inputs

Juyeon Kim, Chaeyeon Yi, Yun Am Seo

原文摘要

Frost protection requires local warnings where leaf-sensor inputs are unavailable. In the frost literature we surveyed, physics entered machine-learning models through inputs, numerical-model coupling, or losses, rather than model structure. We develop a transformer-compatible module that embeds leaf energy-balance physics in freezing-probability forecasts: an energy-balance temperature reference and a learned residual predict leaf temperature, which drives a multiplicative gate imposing a temperature-dependent probability cap. We mathematically prove conditional monotonicity and an alarm boundary, and test whether placing the same information in the output pathway or in attention yields different benefits. We evaluated 12 hourly leads at 19 Korean stations over five frost seasons, with and without leaf-sensor inputs. In the 2025-2026 hold-out season without these inputs, our time-token transformer (PET-E) achieved a lead-mean critical success index (CSI) of 0.516 versus 0.478 for fixed-configuration, joint-lead LightGBM, with significant gains at all 12 leads, and the fraction of alarms at observed leaf temperatures of at least 2 degrees C fell from 0.087 to 0.051 relative to the unmodified backbone. Across the hold-out and a retrospective 2024-2025 evaluation, the module reduced Brier scores and warm-surface alarm fractions in both the time-token transformer and iTransformer, with no significant CSI decrease at any lead. At held-out stations without static or leaf-sensor inputs, both module-equipped backbones exceeded LightGBM at all 12 leads (CSI 0.468 and 0.467 versus 0.437). In the time-token backbone, the temperature pathway reduced this alarm fraction in all four settings, whereas the attention prior increased CSI in three. These findings link an explicit temperature-dependent probability cap to improved forecasts and distinguish output-side from attention-based embedding.

stat.AP · cs.LG · physics.ao-ph