跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1382新增论文
+1088其中 AI 相关
+175已有论文修订
+59新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-18 12:34各信源进度 →

统计口径与数据新鲜度

统计 2026-11-17 12:58 — 2026-11-18 12:58(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-18 12:34库内论文最新更新时间:2026-11-18 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

26,054 已收录论文21,703 AI 相关7,828 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
新论文 · v1arXiv:2611.20786

ThermoSight: From Appearance to Internal Thermofluid Fields via Physics-Guided Neural Reconstruction

Yuhao Fang, Chenglin Lu, Hefei Ling, Chun Lou

原文摘要

Most neural reconstruction methods focus on reproducing scene appearance, yet inferring physical states from visual observations is essential for machine understanding of the physical world. Reconstructing the internal temperature and soot fields of radiating thermofluids such as flames is challenging yet essential for improving energy efficiency and assessing heat exposure and fire spread. In flames, temperature and soot concentration jointly govern visible emission, and soot self-absorption alters the light that reaches each camera. With limited views, changes in the two fields can offset one another in the recorded RGB images, making temperature and soot difficult to disentangle. ThermoSight, a physics-guided neural framework for scientific imaging, jointly reconstructs continuous three-dimensional temperature and soot volume fraction fields from limited calibrated flame images without field-level ground truth during optimization. A differentiable spectral model links these fields to measured RGB through thermal emission, self-absorption, and calibrated camera responses. Temperature-dependent emission spectra and wavelength-dependent attenuation constrain shared fields across RGB channels, reducing temperature-soot ambiguity. Chromaticity consistency, observation-derived spatial constraints, and soot regularization complement intensity fitting. In a synthetic ablation, wavelength-resolved attenuation reduces temperature RMSE in the hot, sooty region from 234 to 112 K relative to a three-channel approximation, with nearly identical RGB PSNR (65.23 vs. 65.24 dB). Measured data yield coherent fields and competitive RGB reconstructions. These results demonstrate that physics-guided neural fields recover interpretable internal physical quantities beyond visually consistent appearance.

cs.CV · physics.app-ph