跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1112新增论文
+875其中 AI 相关
+133已有论文修订
+97新增 AI 导读

arXiv 最近完成扫描:2026-11-20 04:39 · 全站最近入库:2026-11-19 19:09各信源进度 →

统计口径与数据新鲜度

统计 2026-11-19 05:14 — 2026-11-20 05:14(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-20 04:39最近发现新增版本:2026-11-19 19:09库内论文最新更新时间:2026-11-19 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

27,982 已收录论文23,249 AI 相关8,559 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-20 04:38(北京时间)
版本更新 · v3arXiv:2609.20151

Ischemic Stroke Segmentation and Net Water Uptake Quantification on Multicenter Non-Contrast CT Using Supervised Target-Domain Adaptation

Linus Britt, Maximilian Nielsen, Susan Klapproth, Andre Kemmling, Michael H. Lev, Gabriel Broocks, Rene Werner, Thilo Sentker

原文摘要

Quantitative assessment of infarct hypodensity on non-contrast computed tomography (NCCT), including net water uptake (NWU), requires manual or semi-manual lesion delineation, often guided by CT perfusion or diffusion-weighted MRI, limiting clinical applicability. Automated NCCT segmentation could enable such biomarker extraction but remains challenging across heterogeneous multicenter data. This study developed and externally tested a deep learning framework for ischemic stroke segmentation and NWU quantification on NCCT. In this retrospective multicenter study of 801 patients from four datasets, an nnU-Net-based model with foundation-model initialization, extended by modules comparing local features with the contralateral hemisphere, was trained on NCCT scans from the University Medical Center Hamburg-Eppendorf and the Acute Ischemic Stroke Dataset. The model was fine-tuned on target-domain subsets of the Boston (n=11) and ISLES (n=75) datasets, with evaluation on held-out cases. Segmentations and NWU were compared with expert references. Internally, mean Dice increased from 0.53 (conventional nnU-Net) to 0.57 (proposed approach). After fine-tuning, the proposed approach achieved median Dice of 0.56 for acute lesion segmentation (Boston) and 0.26 for post-treatment final-infarct prediction (ISLES), where small lesions predominated. For lesions >=30 mL, median Dice increased to 0.67 and 0.57, respectively. On the Boston dataset, automated and reference NWU agreed (concordance correlation coefficient 0.93, mean absolute error 1.24 percentage points). Contralateral feature comparison and target-domain adaptation supported NCCT-only infarct segmentation across heterogeneous external cohorts, although performance was lower for post-treatment final-infarct prediction. The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging or manual annotation.

cs.CV