跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+806新增论文
+644其中 AI 相关
+92已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-20 08:48 · 全站最近入库:2026-11-20 19:58各信源进度 →

统计口径与数据新鲜度

统计 2026-11-20 11:28 — 2026-11-21 11:28(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-20 08:48最近发现新增版本:2026-11-20 19:58库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

28,961 已收录论文24,030 AI 相关8,912 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-20 08:46(北京时间)
新论文 · v1arXiv:2611.25840

Harnessing Medical Visual-Language Models with Agentic Evidence Management

Qiming Huang, Hanze Dong, Jipeng Zhang, Mike Zheng Shou, Xinxing Xu, Furu Wei

原文摘要

Medical vision-language agents increasingly rely on segmentation tools, and recent work has focused on acquiring the right mask, often treating a good mask as the end point of tool use. But do these agents use the resulting evidence effectively? To answer this question, we need a benchmark that separates evidence use from segmentation quality, spans multiple medical image types, and allows the same mask to be presented in different ways. Existing medical VQA datasets do not jointly provide these properties. We therefore construct Mask-Evidence MedVQA, a 2.5K-example benchmark spanning four image types, where each question is paired with an answer-relevant ground-truth mask and multiple possible renderings. Our study reveals two limitations of direct tool use. First, evidence presentation matters. Different renderings of the same fixed mask can substantially change model behavior. Second, masks introduce an evidence trade-off. Highlighting a relevant region can expose diagnostic evidence the model previously missed, but the added visual cue can also induce incorrect associations. As a result, even a ground-truth mask can correct some answers while turning initially correct ones into incorrect ones. Together, these findings show that acquiring the right mask is not enough. An agent must also decide how to present the evidence and whether it should change the answer. We therefore introduce TUNE (Tool Use is Not Enough), an evidence-management harness that explicitly manages what evidence to acquire, how to present it, and whether to accept the resulting answer update. Across three public medical VQA benchmarks, evidence management improves the fine-tuned Qwen3.5-9B backbone's mean accuracy by 4.0 percentage points. Full TUNE improves over direct tool use by 9.1 points on average across seven benchmarks and achieves competitive results against existing medical VLMs and agents.

cs.CV · cs.AI