跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1095新增论文
+868其中 AI 相关
+92已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-17 04:58 · 全站最近入库:2026-11-17 13:07各信源进度 →

统计口径与数据新鲜度

统计 2026-11-16 13:12 — 2026-11-17 13:12(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-17 04:58最近发现新增版本:2026-11-17 13:07库内论文最新更新时间:2026-11-16 17:16

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

24,849 已收录论文20,754 AI 相关7,213 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 4 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-17 04:57(北京时间)
版本更新 · v2arXiv:2605.22414

Towards Clinically Interpretable Ophthalmic VQA via Spatially-Grounded Lesion Evidence

Xingyue Wang, Bo Liu, Meng Wang, Zhixuan Zhang, Chengcheng Zhu, Huazhu Fu, Jiang Liu

原文摘要

Visual Question Answering (VQA) holds great promise for clinical support, particularly in ophthalmology, where retinal fundus photography is essential for diagnosis. However, ophthalmic VQA benchmarks primarily emphasize answer accuracy, neglecting the explicit visual evidence necessary for clinical interpretability. In this work, we introduce FundusGround, a new benchmark for clinically interpretable ophthalmic VQA with spatially-grounded lesion evidence. Specifically, we propose a three-stage pipeline that collects 10,719 fundus images with 15,595 image-level meticulously annotated lesions. To ensure anatomical consistency and clinical validity, all lesions are spatially localized using the Early Treatment Diabetic Retinopathy Study (ETDRS) grid, enabling standardized mapping to nine clinically meaningful retinal regions. Built upon this structured lesion evidence, 72,706 questions are then generated spanning four formats: open-ended, closed-ended, single-choice, and multiple-choice. We further benchmark multiple general- and medical- large vision-language models using dual metrics for answer accuracy and lesion-level reasoning. The experiments demonstrate that incorporating lesion-level visual evidence consistently improves model performance and transparency, highlighting the necessity of explicit spatial grounding for reliable and explainable ophthalmic VQA.

cs.CV · cs.AI

新论文 · v1arXiv:2611.13045

MICRO: A Surgery-Phase Retinal Image Rigid Registration Benchmark and One-Step Frequency-Structure Similarity Registration Learning

Mingdao Gong, Yan Hu, Mingzhen Yuan, Jialu Zhang, Junming Feng, Yiming Jiang, Jing Ma, Jinghua Liu 等 12 位作者

原文摘要

Precise multimodal retinal image rigid registration (MRIRG) is essential for aligning cross-modal vessel structures, offering critical guidance for ophthalmic surgery. Despite its significance, the advancement of MRIRG is hindered by the lack of publicly available multimodal retinal image rigid registration datasets spanning various ophthalmic surgery phases (e.g., preoperative, intraoperative, and postoperative). To address this issue, we introduce the MICRO dataset, a large-scale MRIRG benchmark, comprising 1,365 cross-modal retinal image pairs with standardized annotations across all ophthalmic surgery phases. Moreover, existing deep registration methods achieve competitive MRIRG results via a two-step segmentation-then-detection framework, but segmentation quality heavily constrains their performance. We argue that this dependency stems from an implicit need for keypoint topology constraints, which have not been exploited for MRIRG through a one-step registration framework. Inspired by the above analysis, we propose a novel One-step Frequency-Structure Similarity Registration (OFS2Reg) learning framework for MRIRG that leverages the potential of cross-modal vessel structure similarities to construct keypoint topology constraints under a shared detection network. To be specific, OFS2Reg applies a well-designed frequency-guided structure preservation descriptor to construct coarse keypoint topology constraints in descriptors by highlighting significant vessel structures. Additionally, we develop a new cross-modal vessel structure similarity learning method that refines cross-modal keypoint topology constraints to precisely align pixel-level cross-modal vessel structures by leveraging cross-modal vessel structure similarity priors.

cs.CV

新论文 · v1arXiv:2610.40121

Learning a Motion Manifold to Constrain Ambiguity in Unsupervised 4D Medical Image Interpolation

Haojin Li, Huazhu Fu, Heng Li, Jiang Liu

原文摘要

Unsupervised 4D medical image interpolation reconstructs intermediate anatomical states from temporally sparse observations without intermediate supervision. Distinct motion fields may attain comparable endpoint agreement while producing different intermediate anatomy, giving rise to motion ambiguity. This ambiguity is difficult to constrain when many independently adjustable motion variables must be estimated from the observed endpoints. We develop a framework that learns a motion manifold to restrict candidate motion fields while retaining sample-specific variation. Cross-Sample Spectral Basis Learning extracts recurring motion structure from endpoint-derived dense estimates and encodes it in a shared spectral basis. Sample-Conditioned Cayley Basis Reorientation uses predicted motion coordinates to rotate the effective motion directions for each endpoint pair without increasing the number of independent coordinates. Their composition defines a nonlinear family of complete velocity fields across endpoint pairs, accommodating anatomical and motion-state differences within a restricted representation. Integrating each predicted field supports bidirectional reconstruction at arbitrary intermediate times. Theoretical analysis establishes sufficient conditions under which endpoint observations distinguish nearby motions within the learned family. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance among the evaluated methods trained without intermediate volumes and competitive results against methods using intermediate supervision.

cs.CV

新论文 · v1arXiv:2610.38389

Visually Irrelevant Hallucinations in Medical Vision-Language Models

Ke Zou, Nan Zhou, Tao Yang, Meng Liu, Linchao He, Zehui Liao, Ling Huang, Guangren Huang 等 12 位作者

原文摘要

Medical vision-language models (VLMs) show strong performance in radiology report generation (RRG) and medical visual question answering (Med-VQA), producing free-form clinical descriptions and answers from medical images. However, they may generate clinically meaningful statements that lack visual evidence or contradict image content. We refer to these errors as visually irrelevant hallucinations and investigate them at the phrase level. We propose CLEAR (Counterfactual Localized Evaluation of Alignment and Response), a model-agnostic post-hoc framework for phrase-level hallucination risk estimation. CLEAR decomposes generated responses into visually assessable clinical phrases. For each phrase, phrase-conditioned grounding identifies a candidate visual region, which is selectively perturbed by a localized counterfactual intervention. CLEAR characterizes the intervention using two complementary auditing cues: response cues, capturing semantic and clinically meaningful changes in the generated response, and alignment cues, measuring changes in image-phrase compatibility. These cues are normalized and jointly modeled to estimate phrase-level hallucination risk. Across four datasets spanning RRG and Med-VQA, CLEAR outperforms state-of-the-art hallucination detection baselines across multiple medical and general-purpose VLMs. On MIMIC-CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its effectiveness is further validated on a GT-derived controlled VIH benchmark. These results establish visually irrelevant hallucination as an important fine-grained reliability failure mode in medical VLMs and demonstrate the value of model-agnostic visual-support auditing for more trustworthy multimodal clinical generation.

cs.CV