跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1085新增论文
+884其中 AI 相关
+130已有论文修订
+94新增 AI 导读

arXiv 最近完成扫描:2026-11-19 06:59 · 全站最近入库:2026-11-19 06:59各信源进度 →

统计口径与数据新鲜度

统计 2026-11-18 09:12 — 2026-11-19 09:12(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-19 06:59最近发现新增版本:2026-11-19 06:59库内论文最新更新时间:2026-11-18 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

26,871 已收录论文22,375 AI 相关8,156 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-19 06:57(北京时间)
新论文 · v1arXiv:2611.20129

Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes

Indranil Mallick, Paromita Roy

原文摘要

Decision models are a new class of language model that, instead of generating text, choose one option per question from a fixed list and return a probability for every option. They have not yet been evaluated on clinical text. We evaluated two open-weights decision models, Nimble 9B and Tev1 4B, for extracting 25 fields from 1,113 oral cavity cancer pathology reports from a single centre, against a prospectively maintained clinical database. We compared them with two generative models: Qwen3.5 9B, run locally, and GLM-5.3-flash, run through a cloud API. Tev1 reached a mean field accuracy of 0.917 (95% CI 0.913 to 0.920), the same as Qwen3.5 9B (0.918; p = 0.26), and was four times faster (15 s against 61 s per report). Nimble reached 0.862 and GLM-5.3-flash 0.986. Both decision models matched GLM-5.3-flash on simple dichotomous categories. They were weak on measurements binned into categories, on fields whose correct answer was not reported, and on some complex decisions (e.g. involved margins). We found that the main cause of the inferior performance of Nimble's came from asking 25 questions in one request: with two questions per request, its accuracy improved. Pooled over fields, the returned probabilities were well calibrated (expected calibration error 0.022 and 0.026), but they did not flag systematic errors within single fields. A simulated strategy of sending answers with a probability below 0.94 to GLM-5.3-flash raised Tev1's accuracy to 0.982, with 38% of answers escalated. Decision models can extract explicitly stated findings from pathology reports quickly on local hardware and return useful probabilities. They should be validated in the configuration in which they will be used, restricted to the fields in which they are reliable, and combined with other methods for numeric values.

cs.CL · cs.AI · cs.LG