跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1202新增论文
+980其中 AI 相关
+155已有论文修订
+1新增 AI 导读

arXiv 最近完成扫描:2026-11-26 17:41 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-25 18:35 — 2026-11-26 18:35(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-26 17:41最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-26 17:39(北京时间)
新论文 · v1arXiv:2611.22896

Impact of Pretraining Length, Model Size, and Annotation Budget on Downstream Clinical Tasks of Foundation Models in Radiotherapy

Alejandro Cortina Uribe, Sidsel Højklint Poulsen, Ivan Richter Vogelius, Jens Petersen

原文摘要

Cone-beam CT (CBCT) scans acquired during radiotherapy capture changes such as tumor shrinkage and radiation-induced tissue changes, offering great potential for foundation models that help monitor individual treatment responses. However, to our knowledge, no large-scale pretrained models for radiotherapy CBCT exist, and evaluating modeling choices is difficult since downstream tasks are not known in advance. We examine how pretraining length, model size, and finetuning strategy relate to downstream clinical performance, and how metrics tracked during pretraining correlate with it. We pretrain vision transformer encoders with masked image modeling on about 150,000 raw 3D radiotherapy CBCT scans, tracking representation quality via validation loss, effective rank, and linear probing. Downstream tasks are classification of feeding tube presence ($n=51,135$ CBCTs, $1,562$ patients) and clinical characteristics (T-, N-stage, sex, age, tumor site; $n=1,278$ patients) in head and neck cancer. We compare low-rank adaptation (LoRA) and full finetuning against no pretraining, varying annotated dataset size. Pretext validation loss was the most consistent predictor of downstream performance; effective rank and linear probing were also associated, but not consistently across model sizes and finetuning methods. LoRA performed comparably to full finetuning while training only 0.5-2.5% of the parameters. Fully finetuned models consistently outperformed models without pretraining across all sizes, with AUROC 0.91-0.97 vs. 0.58-0.85 for feeding tube classification and 0.99-1.00 vs. 0.71-0.97 for sex classification. Model size had only a small, inconsistent effect, suggesting smaller models suffice at lower computational cost. Code and pretrained models (non-commercial license): https://github.com/alexCortinaU/RT-CBCT_SSL

cs.CV