跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1199新增论文
+950其中 AI 相关
+132已有论文修订
+97新增 AI 导读

arXiv 最近完成扫描:2026-11-20 08:48 · 全站最近入库:2026-11-20 16:53各信源进度 →

统计口径与数据新鲜度

统计 2026-11-19 18:28 — 2026-11-20 18:28(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-20 08:48最近发现新增版本:2026-11-20 16:53库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

28,609 已收录论文23,738 AI 相关8,785 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-20 08:46(北京时间)
新论文 · v1arXiv:2610.37312

Self-Referenced Diagnosis of SPAD Dark-Count-Rate Switching for Quantum Communication Receivers

Yu Luo, Lina Pu, Yaroslav Koshka, Chun-Hung Liu, Junming Diao

原文摘要

Single-photon avalanche diodes (SPADs) are essential components of quantum communication receivers. In practical systems, some SPADs exhibit intrinsic step-like changes in dark-count rate (DCR), commonly referred to as random telegraph signal (RTS) noise. Similar RTS-like variations, however, can also arise from stray light, temperature-dependent threshold crossings, cable disturbances, electrical interference, and other readout artifacts. Distinguishing intrinsic RTS from these artifacts is important because they originate from different mechanisms and require different corrective actions. We present a self-referenced diagnostic that primarily uses the low-to-high afterpulse-yield ratio R, together with complementary checks based on DCR-state reproducibility, cross-channel behavior, and event timing. Four commercial SPAD modules were monitored in darkness for more than 920 h. Three exhibited intrinsic DCR switching of 44.59%, 19.33%, and 2.77%, with corresponding R values of $0.9996\pm0.0027$, $1.0050\pm0.0023$, and $1.0027\pm0.0043$, all consistent with unity. Controlled experiments reproduced temperature-related threshold crossings, light leakage, cable-contact artifacts, and artificial electrical injection. These artifacts produced distinct correlation and timing signatures: temperature-related threshold crossings gave intermediate pair-survival responses, cable disturbances and electrical injection generated sub-dead-time events, while light leakage produced simultaneous cross-channel switching and nonreproducible DCR levels. Combining R with orthogonal timing and DCR-based checks provides a practical self-referenced diagnostic framework for distinguishing intrinsic RTS from non-intrinsic artifacts using primarily time-tagged dark-count data.

cs.ET