跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1680新增论文
+1333其中 AI 相关
+187已有论文修订
+59新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-17 23:35各信源进度 →

统计口径与数据新鲜度

统计 2026-11-17 09:44 — 2026-11-18 09:44(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-17 23:35库内论文最新更新时间:2026-11-17 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

25,786 已收录论文21,491 AI 相关7,725 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 4 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
新论文 · v1arXiv:2611.15658

Embedded Sim-to-Real Visual Servoing: Learned Reaching and Force-Guided Placement

Dezhi Sun, Duy Khang Banh, Kenan Niu

原文摘要

Embedded perception-to-control systems must combine visual targeting with reliable contact handling under tight computational constraints. We present a shared architecture on an NVIDIA Jetson AGX Orin controlling a Franka Research 3 through Cartesian impedance control. RealSense D435i observations, YOLO11-seg segmentation, depth back-projection, and hand--eye calibration provide metric robot-frame targets. We compare two strategies: compact proximal policy optimization (PPO) policies transferred from simulation for object- and hole-region reaching, and force-guided Cartesian placement using approximately 2 N normal contact and spiral search. The PPO policies achieved 87.2% and 83.1% success over 1000 simulation episodes each. Across 50 real-robot trials per strategy, the learned hybrid and force-guided analytical pipelines achieved 70.0% and 74.0% completion, respectively. Mean perception latency with TensorRT was 34.55 ms. These results support an embedded architecture combining learned free-space reaching with explicit contact correction.

cs.RO

新论文 · v1arXiv:2611.15650

Single-View RGB-D Force--Deformation Estimation for Robotic Manipulation of Elasto-Plastic Materials

Dezhi Sun, Marijn van Hilten, Kenan Niu

原文摘要

Persistent deformation complicates elasto-plastic manipulation by coupling physical interaction with spatially distributed shape changes. We investigate the force--deformation relationship using a standard robot, a single eye-in-hand RGB-D camera, and intrinsic force estimates. A 7-DoF Franka Emika FR3 performs normal indentations while an Intel RealSense L515 captures pre- and post-contact surfaces. Point-cloud processing localizes deformation and estimates displaced volume. Force--volume characterization includes 27 measurements over nine force levels. A compact multilayer perceptron (MLP), trained on 52 force--volume pairs at four levels, achieves a held-out RMSE of 1.857 N and $R^2=0.440$. A separate comparison shows lower error for a quadratic model at 16 N and for the MLP at 19 and 23.5 N. An eight-step experiment at 4 N per interaction demonstrates cumulative deformation localization from the second indentation onward. These results establish a practical measurement basis for deformation-aware manipulation using intrinsic force estimates and single-view geometry.

cs.RO

新论文 · v1arXiv:2611.04604

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

Tianyuan Wang, Kenan Niu, Stefano Stramigioli

原文摘要

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

eess.IV · cs.CV

新论文 · v1arXiv:2610.37127

MCP-Net: Real-Time Coronary Perception Network and Topological Analysis for Robotic Guidewire Navigation

Sahar Nasirihaghighi, Tianyuan Wang, Kenan Niu, Stefano Stramigioli

原文摘要

Coronary guidewire navigation during percutaneous coronary intervention requires continuous interpretation of vessel anatomy, guidewire position, and target stenosis under two-dimensional X-ray fluoroscopy. While existing approaches commonly address vessel segmentation or device localization as separate tasks, a robotic system requires a more structured perception of the coronary scene to support downstream navigation. In this work, we present a simulation-driven framework centered on a Multi-Task Coronary Perception Network (MCP-Net) for robotic guidewire navigation, integrating coronary vessel segmentation, vascular topology extraction, and roadmap generation. Starting from three-dimensional coronary CT angiography, we generate simulated fluoroscopy images containing vascular structures, simulated guidewires, stenotic lesions with varying severity, and diverse vascular geometries, together with simulation-derived ground truth. MCP-Net jointly performs coronary vessel segmentation, guidewire-tip localization, and stenosis localization from a single fluoroscopic frame. These predictions are subsequently converted into a structured vascular graph containing centerlines, bifurcations, endpoints, branch directions, and branch angles. By associating the predicted stenosis with this graph, the framework generates a roadmap from the automatically selected graph root toward the target lesion. The results demonstrate that the proposed framework can jointly recover coronary perception targets and transform them into an interpretable vascular representation suitable for downstream robotic navigation.

cs.CV · cs.RO