跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+479新增论文
+361其中 AI 相关
+64已有论文修订
+93新增 AI 导读

arXiv 最近完成扫描:2026-11-16 01:34 · 全站最近入库:2026-11-16 21:56各信源进度 →

统计口径与数据新鲜度

统计 2026-11-15 22:24 — 2026-11-16 22:24(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-16 01:34最近发现新增版本:2026-11-16 21:56库内论文最新更新时间:2026-11-14 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

23,827 已收录论文19,941 AI 相关6,922 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-16 01:33(北京时间)
新论文 · v1arXiv:2611.17968

TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT Images

Jakob Wasserthal, Daniel Hinck, Martin Segeroth, Joshy Cyriac, Denis Berdajs, Jules Miazza, Maurice Pradella

原文摘要

Purpose: To develop and evaluate a fully automated, open-source tool that measures aortic diameters at 11 standardized landmarks from the aortic annulus to the bifurcation on any CT image, following current guideline recommendations. Materials and Methods: This retrospective single-center study included 239 arterial phase CT angiography examinations of 230 patients (median age, 65 years [range, 18-99 years]; 163 men) performed between April 2025 and October 2026 (209 electrocardiographically [ECG] gated). The tool locates landmarks from TotalSegmentator segmentations of aortic branches and vertebrae and measures the maximum diameter at each. A senior radiologist reviewed and, where needed, corrected the automated measurements to create the reference standard. Agreement was assessed with mean absolute error (MAE), bias, and differences greater than 2 mm. Results: Across all landmarks, MAE was 1.06 mm (95% CI: 0.91, 1.22), and 86.6% (95% CI: 84.4, 88.5) of differences were 2 mm or less. The tool measured slightly larger diameters (bias, 0.45 mm [95% CI: 0.34, 0.57]). The sinuses of Valsalva had the largest MAE (2.17 mm [95% CI: 1.59, 2.86]). For 1.2% of landmarks, the automatic measurement failed. Examination-level MAE did not differ significantly by pathology, atherosclerosis grade (P=.95), or ECG gating (P=.14). Examinations with mural thrombus more often had an MAE greater than 2 mm (50% [95% CI: 31, 69] vs 20%; P=.03). Conclusion: The tool measured aortic diameters at 11 landmarks along the entire aorta with an MAE of about 1 mm, below published interreader variability. Agreement was lower at the aortic root and with mural thrombus. Code availability: The tool is open source and freely available at https://github.com/wasserth/TotalSegmentator.

cs.AI