跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-28 09:33 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-27 20:53 — 2026-11-28 20:53(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-28 09:33最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-28 09:30(北京时间)
版本更新 · v2arXiv:2606.31521

Distortion-Corrected Diffusion MRI Using Rotated-View EPI and Joint Field-Map/Image Estimation with Gaussian Primitives

Wenqi Huang, Zhitao Li, Nan Wang, Yimeng Lin, Mengze Gao, Yurui Qian, Sevgi Gokce Kafali, Xiaozhi Cao 等 11 位作者

原文摘要

Echo planar imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field, the distortion-free image, and the shot-to-shot phase directly from k-space data, without depending on an intermediate parallel-imaging reconstruction. All three are represented as superpositions of Gaussian primitives embedded within an EPI forward model; the explicit, continuous parameterization captures both smooth regions and tissue boundaries and is evaluated on rotated sampling grids without resampling. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Acquiring the blip-up/blip-down data at several phase-encoding orientations, the rotated-view principle of PROPELLER applied to full-FOV single-shot EPI, distributes distortions across orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI at R=4 and 5, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value.

eess.IV · cs.CV · eess.SP