跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+91新增 AI 导读

arXiv 最近完成扫描:2026-11-22 08:44 · 全站最近入库:2026-11-21 12:19各信源进度 →

统计口径与数据新鲜度

统计 2026-11-21 14:17 — 2026-11-22 14:17(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-22 08:44最近发现新增版本:2026-11-21 12:19库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

29,158 已收录论文24,181 AI 相关8,992 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-22 08:42(北京时间)
新论文 · v1arXiv:2611.24052

From Data to Valves: A Self-Learning, Production-Grade Edge Stack for Sustainable HVAC Control

Abbas Raza Ali, Muhammad Hamza Rehman, Xu Li, Muhammad Ajmal Siddiqui

原文摘要

Learned HVAC controllers rarely leave the simulator, and those that do are typically trained offline, frozen at deployment and retrained from the cloud. We present a production stack in which three learning components run on one NVIDIA Jetson Orin gateway per building, adapt continuously from the building's own data, and verify their own effect. (a) A compact transformer-encoder forecaster, one per equipment group with learned per-unit embeddings, predicts every air-side unit's next-cycle temperature and learns prequentially, one gradient step per five-minute cycle, behind five independent gates that bound the influence of any corrupt reading. (b) A distributional soft actor-critic agent, one shared policy across unit types, converts the measured state into a chilled-water valve position under a structural safety envelope that no learned component can soften; its second generation learns nightly on the device from recorded transitions alone, with a behaviour anchor and critic calibration terms, is scored by four model-free metrics and promoted by atomic hot-swap. (c) A change-point regression baseline held to ASHRAE Guideline 14 supplies the counterfactual against which savings are certified. On eighteen months of data from a hotel the forecaster converges from random weights within a week and reaches 0.37, 0.39 and 0.11 degree C MAE for air-handling, fresh-air and fan-coil units with no retraining event; on a different hotel the baseline reproduces a 46-day held-out period to within 0.07%. The RL agent has completed its in-simulator campaign and runs in shadow on 104 units; we report measured latency and memory of every service on a shared 15 GB device, the systems lessons of the campaign, and precisely what the evidence does and does not yet establish.

cs.LG · cs.AI