跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+92新增 AI 导读

arXiv 最近完成扫描:2026-11-23 01:07 · 全站最近入库:2026-11-21 12:19各信源进度 →

统计口径与数据新鲜度

统计 2026-11-22 13:09 — 2026-11-23 13:09(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-23 01:07最近发现新增版本:2026-11-21 12:19库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

29,158 已收录论文24,181 AI 相关8,992 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-23 01:05(北京时间)
新论文 · v1arXiv:2611.18522

Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

Davide Tondi, Vijay K. Dubey, Collin E. Haese, Colton J. Kostelnik, Mrudang Mathur, Sumedh Seetharam, Amin Silvani, Alison M. Pouch 等 26 位作者

原文摘要

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

cs.CE