跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+197新增论文
+151其中 AI 相关
+16已有论文修订
+91新增 AI 导读

arXiv 最近完成扫描:2026-11-22 06:41 · 全站最近入库:2026-11-21 12:19各信源进度 →

统计口径与数据新鲜度

统计 2026-11-21 08:13 — 2026-11-22 08:13(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-22 06:41最近发现新增版本:2026-11-21 12:19库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

29,158 已收录论文24,181 AI 相关8,992 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-22 06:39(北京时间)
版本更新 · v2arXiv:2611.10502

Distinguishing Extraction Failures and Clinical Discordance with LLM Uncertainty on Radiology Reports

Jerjes Aguirre-Chavez, Shant Malkasian, Roshun Sankaran, Brendan Crabb, Albert Hsiao

原文摘要

Large language models (LLMs) are increasingly used to structure data from unstructured text, but extraction errors remain inevitable. We evaluated whether LLM uncertainty could distinguish extraction failure from true clinical discordance. In 5{,}225 vessels from 1{,}045 patients undergoing coronary CT angiography (CCTA) for suspected coronary artery disease (CAD), we evaluated token-level and self-reported LLM uncertainty during extraction of vessel-level stenosis severity. Extraction failure was defined as disagreement between LLM-extracted stenosis and expert annotations. Clinical discordance was defined as disagreement in obstructive CAD status between CCTA and subsequent invasive coronary angiography (ICA). Incremental discrimination was assessed after adjustment for stenosis severity, calcium burden, and coronary vessel. Extraction failure was evaluated in 1{,}077 vessels from 253 patients with expert annotations, and clinical discordance in 1{,}641 vessels from 729 patients undergoing ICA within 90 days. Token-level Stenosis Margin showed the strongest association with extraction failure (adjusted OR, 4.15 [95\% CI, 2.57--6.69]; $P<0.001$) and clinical discordance (adjusted OR, 1.22 [95\% CI, 1.04--1.43]; $P=0.118$). Stenosis Margin significantly improved discrimination of extraction failure ($Δ$AUC, +0.06 [95\% CI, +0.03 to +0.09]; $P=0.001$), but not clinical discordance ($Δ$AUC, +0.01 [95\% CI, $-0.00$ to +0.02]; $P=0.245$). In a nested cohort of 138 vessels from 57 patients, 38 of 42 clinically discordant vessels (90\%) were extracted correctly. LLM uncertainty improved identification of extraction failure but not clinical discordance, suggesting that uncertainty may identify errors introduced during data extraction but may not generalize to discordance in underlying clinical data.

cs.CL