跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+758新增论文
+578其中 AI 相关
+94已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-17 04:58 · 全站最近入库:2026-11-17 04:58各信源进度 →

统计口径与数据新鲜度

统计 2026-11-16 10:34 — 2026-11-17 10:34(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-17 04:58最近发现新增版本:2026-11-17 04:58库内论文最新更新时间:2026-11-14 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

24,106 已收录论文20,158 AI 相关7,049 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-17 04:57(北京时间)
版本更新 · v2arXiv:2609.38437

基于对操作者推断的具身感知控制:一项仿真研究

Embodiment-aware control by inference over the operator: a simulation study

Sara Falcone

AI 速读 基于摘要

提出一种具身感知控制器,通过隐式注视与瞳孔信号推断操作者的具身感及视-本体感觉线索权重,在显式偏好下选择有界设备设置,并在合成操作者仿真中评估。

cs.RO · cs.HC · q-bio.NC

查看原文摘要

Teleoperation and assistive devices are tuned for channel fidelity, while whether the operator experiences the device as part of the body, the Sense of Embodiment, is measured only afterwards. Minimizing the mismatch between the operator's predictions and the returned feedback fails twice: the predictions cannot be observed, and removing feedback minimizes the objective. We formulate an embodiment-aware controller that instead infers the operator's embodiment and visuo-proprioceptive cue weighting from implicit gaze and pupil signals and task outcome, and chooses bounded device settings under explicit preferences, cast as a discrete Active Inference agent. In simulations with heterogeneous synthetic operators, it raised embodiment from 0.76 to 1.66 on a 0-2 scale over the best fixed setting, within 0.02 of an oracle across ten random seeds; adaptation that did not read the operator gained nothing, and a prediction-error minimizer withheld feedback. An expected-utility controller with the same inference did as well, so the benefit comes from inference over the operator with explicit preferences, not from information seeking. Rules on a single signal came close when that signal was informative and failed when it was not; the controller degraded less, but failed when it trusted an uninformative signal unless briefly calibrated. Against published human data, the model reproduced the embodiment-performance relation, and embodiment developed on a plausible time scale. The embodiment signals were redundant when task success tracked embodiment and became the controller's objective when it did not. Studies with people must first establish calibrated cue-weighting signals and effort-independent embodiment signals.