跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+979新增论文
+781其中 AI 相关
+119已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-20 08:48 · 全站最近入库:2026-11-20 19:58各信源进度 →

统计口径与数据新鲜度

统计 2026-11-20 07:53 — 2026-11-21 07:53(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-20 08:48最近发现新增版本:2026-11-20 19:58库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

28,961 已收录论文24,030 AI 相关8,912 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-20 08:46(北京时间)
新论文 · v1arXiv:2611.23672

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg, Bo Zhou

原文摘要

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($μ$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $μ$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $μ$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $μ$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $μ$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

cs.CV