跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+549新增论文
+443其中 AI 相关
+62已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-21 12:19 · 全站最近入库:2026-11-21 12:19各信源进度 →

统计口径与数据新鲜度

统计 2026-11-20 17:59 — 2026-11-21 17:59(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-21 12:19最近发现新增版本:2026-11-21 12:19库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

29,158 已收录论文24,181 AI 相关8,992 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-21 12:17(北京时间)
版本更新 · v2arXiv:2609.07151

Vishing-Tactics-Bench: Forecasting Exploitation Trajectories in Voice Phishing Calls

Jeongmin Lee, Dongmyung Sul, Seung Yun, Jinxia Huang

原文摘要

Voice phishing (vishing) unfolds in real time; by the time a call has ended and post-hoc classification is possible, the harm has already been done. The more actionable question is which concrete harm (Information Gathering or Financial Exploitation) an ongoing call is tactically progressing toward. We present Vishing-Tactics-Bench, a benchmark grounded in Endsley's situation-awareness (SA) framework that recasts vishing defense from after-the-fact fraud classification to harm projection: predicting at each turn whether the call will reach either terminal harm. We adapt MITRE ATT&CK to vishing as a 6-tactic taxonomy (Vishing-Tactics) and label 35,340 scammer utterances across 5,645 synthetic Chinese calls. We define Exploitation Trajectory Forecasting, a survival-style protocol over the two terminal harms with three metrics: AP@k, C-index, and divergence error. Baselines ranging from a Markov heuristic to fine-tuned LLMs show that the tactical trajectory serves as an interpretable representation of the call's tactical state, supporting harm-specific forecasting, which can then be used for the downstream application of intervention selection; a stratified lead-time analysis at a tight false-alarm budget further identifies at what point in a call the trajectory signal yields early warning.

cs.CL

新论文 · v1arXiv:2610.40478

基于CT-to-MRI合成与保形预测的无需MRI的PET精确定量及可靠性评估

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction

Jungwoo Seo, Seung Yun Choi, Kun Ho Lee, Seun Jeon, Byoung Seok Ye, Jiook Cha

AI 速读 基于摘要

作者提出将切片一致的Brownian Bridge扩散模型用于CT-to-MRI合成,并结合保形预测,实现无需个体MRI的淀粉样蛋白PET SUVR定量及其可靠性区间评估。

cs.CV

查看原文摘要

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On $^{11}$C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE $0.016 \pm 0.015$, Pearson $r = 0.9987$) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.