跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1299新增论文
+1041其中 AI 相关
+170已有论文修订
+1新增 AI 导读

arXiv 最近完成扫描:2026-11-26 09:23 · 全站最近入库:2026-11-25 13:23各信源进度 →

统计口径与数据新鲜度

统计 2026-11-25 09:24 — 2026-11-26 09:24(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-26 09:23最近发现新增版本:2026-11-25 13:23库内论文最新更新时间:2026-11-25 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

33,231 已收录论文27,442 AI 相关10,485 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 2 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-26 09:21(北京时间)
新论文 · v1arXiv:2611.04604

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

Tianyuan Wang, Kenan Niu, Stefano Stramigioli

原文摘要

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

eess.IV · cs.CV

新论文 · v1arXiv:2610.37127

MCP-Net: Real-Time Coronary Perception Network and Topological Analysis for Robotic Guidewire Navigation

Sahar Nasirihaghighi, Tianyuan Wang, Kenan Niu, Stefano Stramigioli

原文摘要

Coronary guidewire navigation during percutaneous coronary intervention requires continuous interpretation of vessel anatomy, guidewire position, and target stenosis under two-dimensional X-ray fluoroscopy. While existing approaches commonly address vessel segmentation or device localization as separate tasks, a robotic system requires a more structured perception of the coronary scene to support downstream navigation. In this work, we present a simulation-driven framework centered on a Multi-Task Coronary Perception Network (MCP-Net) for robotic guidewire navigation, integrating coronary vessel segmentation, vascular topology extraction, and roadmap generation. Starting from three-dimensional coronary CT angiography, we generate simulated fluoroscopy images containing vascular structures, simulated guidewires, stenotic lesions with varying severity, and diverse vascular geometries, together with simulation-derived ground truth. MCP-Net jointly performs coronary vessel segmentation, guidewire-tip localization, and stenosis localization from a single fluoroscopic frame. These predictions are subsequently converted into a structured vascular graph containing centerlines, bifurcations, endpoints, branch directions, and branch angles. By associating the predicted stenosis with this graph, the framework generates a roadmap from the automatically selected graph root toward the target lesion. The results demonstrate that the proposed framework can jointly recover coronary perception targets and transform them into an interpretable vascular representation suitable for downstream robotic navigation.

cs.CV · cs.RO