跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+979新增论文
+781其中 AI 相关
+119已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-20 08:48 · 全站最近入库:2026-11-20 19:58各信源进度 →

统计口径与数据新鲜度

统计 2026-11-20 08:03 — 2026-11-21 08:03(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-20 08:48最近发现新增版本:2026-11-20 19:58库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

28,961 已收录论文24,030 AI 相关8,912 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 6 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-20 08:46(北京时间)
新论文 · v1arXiv:2611.17819

Causally Constrained and Uncertainty-Aware Cardiopulmonary Risk Prediction

Yuxiang Lai, Jiashuo Zhang, Liang Zhao, Xiaofeng Yang

原文摘要

Routine chest computed tomography (CT) captures pulmonary, cardiac, and vascular phenotypes that jointly stratify lung cancer and cardiovascular disease, the two leading causes of death in lung-screening populations. Yet clinical risk calculators evaluate each disease in isolation and omit CT findings, whereas unconstrained machine learning overfits small hospital cohorts, learns treatment- and illness-confounded risk directions, and conceals uncertainty when patient records are incomplete. Here we present the Causal Envelope Agent (CE-Agent), a two-stage framework that compiles peer-reviewed epidemiological evidence into explicit constraints on risk-factor weights before any outcome is seen, while estimating local baseline risk and newly added CT phenotypes from cohort data. At deployment, closed-form uncertainty propagation accounts for missing clinical or CT inputs within milliseconds per patient, running over two orders of magnitude faster than Monte Carlo sampling and returning calibrated risk intervals that direct chart review and selective imaging to borderline patients. Across 53,452 lung-screening participants from 33 US hospitals and 6,814 multi-ethnic adults, CE-Agent outperforms cardiovascular calculators in lung screening, exceeds the Pooled Cohort Equations on hard atherosclerotic events while correcting their 1.7-fold risk overestimation, and generalizes from a single hospital or CT scanner to external sites while lowering required sample sizes up to fivefold. Applied unchanged to lung cancer, CE-Agent matches established screening models with accurate calibration even when restricted to risk-factor directions alone, and pairing both predictions improves joint cardiopulmonary triage from a single screening visit.

cs.AI

新论文 · v1arXiv:2611.09866

GRAC:基于图的检索增强字幕生成用于手术场景描述

GRAC: Graph-Based Retrieval-Augmented Captioning for Surgical Scene Description

Rochak Dhakal, Chen Zhao, Soup Cobb, Xin Qian, Xiaofeng Yang, Weihua Zhou

AI 速读 基于摘要

作者提出 GRAC,将手术场景表示为图,并通过检索相似图-字幕对来增强手术场景描述生成。

cs.CV · cs.AI

查看原文摘要

Purpose: Surgical operative reports support procedural documentation, surgical training, performance assessment, and workflow review. However, extracting meaningful information often requires extensive manual review and clinical expertise. Automated surgical scene descriptions could reduce this burden by leveraging recurring surgical activities and prior knowledge. Methods: We propose GRAC (Graph-Based Retrieval-Augmented Captioning), a framework that represents surgical scenes as graphs capturing relationships among instruments, actions, and anatomical structures. Given an input scene graph, GRAC learns to retrieve relevant graph-caption pairs from training data. It compares instrument-tissue interactions between retrieved examples and the input scene, using comparison features to condition retrieved-caption representations during generation. Results: On the EndoVis-18 benchmark, GRAC achieved a CIDEr-D of 5.88, compared with 4.23 for SGT and 3.36 for the strongest conventional Transformer baseline. Exact instrument-action-target triplet-set accuracy reached 52.6%, compared with 32.7% for SGT and 26.2% for the strongest conventional baseline. These results demonstrate improvements in language quality and factual agreement. On TORS, GRAC achieved a CIDEr-D of 5.06, compared with 3.80 for the strongest baseline. Conclusion: GRAC demonstrates that combining structured surgical scene representations with retrieved examples improves surgical scene captioning and produces more contextually meaningful descriptions.

新论文 · v1arXiv:2611.04286

GroundSeek-CXR: Retrospective Evaluation-Guided Active Observation Framework for Multi-Label Chest Radiography Diagnosis

Yihang Fu, Xinyu Liu, Qing Xu, Xiaofeng Yang, Zhen Chen

原文摘要

Chest radiography (CXR) diagnosis is critical for thoracic disease assessment, yet challenged by the need to identify subtle lesions and co-occurring abnormalities across regions. While recent vision-language models can actively observe local regions, existing preference-based methods supervise each observation by its immediate effect on the current diagnosis, failing to capture how each observation and stopping decision contributes to the final diagnosis. To address this issue, we propose GroundSeek-CXR, an active CXR diagnosis framework that learns observation and stopping decisions by retrospectively evaluating them with the final diagnosis. Specifically, we first devise a Retrospective Diagnostic Evaluation (RDE) that scores observation and stop candidates from offline Monte Carlo tree search through independent continuations. Moreover, we design a Retrospective Gap-weighted Preference Optimization (RGPO) that learns from retrospective-score preferences weighted by their score gaps, prioritizing actions that improve diagnostic accuracy. Extensive experiments demonstrate that our GroundSeek-CXR framework outperforms state-of-the-art methods, and improves abnormal-image sample-F1 by 4.48% over immediate-score preference learning.

cs.CV

新论文 · v1arXiv:2611.01888

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

Mojtaba Safari, Parag J. Parikh, Shansong Wang, Mingzhe Hu, Philip Connell, Stanley L. Liauw, Ralph R. Weichselbaum, Zhen Tian 等 9 位作者

原文摘要

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

cs.CV · physics.med-ph

版本更新 · v2arXiv:2510.16973

Foundation Models in Medical Image Analysis: A Systematic Review and Meta-Analysis

Praveenbalaji Rajendran, Mojtaba Safari, Wenfeng He, Mingzhe Hu, Shansong Wang, Jun Zhou, Xiaofeng Yang

原文摘要

Recent advancements in foundation models (FMs) have catalyzed a paradigm shift in medical image analysis. Unlike traditional task-specific artificial intelligence (AI) models, FMs leverage large-scale datasets to learn generalized representations that can be adapted to downstream clinical applications. Despite the rapid proliferation of FM research in medical imaging, there is a lack of unified synthesis that systematically maps the evolution of architectures, training paradigms, and clinical applications across modalities. To address this gap, this review provides a comprehensive and structured synthesis of FMs in medical image analysis by systematically organizing studies into two primary categories: vision-only foundation models (VFMs) and vision-language foundation models (VLFMs), based on their architectural foundations, training strategies, and downstream clinical tasks. A quantitative analysis was conducted on both VFMs and VLFMs to characterize temporal trends in dataset utilization and application domains, along with pooled performance and subgroup analyses. We also critically discuss persistent challenges, including cross-domain generalization, computational scalability, FM evaluation, fairness, and deployment. Finally, we identify key future research directions aimed at enhancing the robustness, interpretability, and clinical integration of FMs, thereby accelerating their translation into real-world medical practice.

cs.CV · cs.AI

新论文 · v1arXiv:2610.34600

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz, Sean Pitroda, Aytekin Oto, Ralph R. Weichselbaum 等 9 位作者

原文摘要

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

cs.CV