跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+979新增论文
+781其中 AI 相关
+119已有论文修订
+95新增 AI 导读

arXiv 最近完成扫描:2026-11-20 08:48 · 全站最近入库:2026-11-20 19:58各信源进度 →

统计口径与数据新鲜度

统计 2026-11-20 08:10 — 2026-11-21 08:10(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-20 08:48最近发现新增版本:2026-11-20 19:58库内论文最新更新时间:2026-11-20 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

28,961 已收录论文24,030 AI 相关8,912 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 3 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-20 08:46(北京时间)
版本更新 · v2arXiv:2610.25058

Triple Overlap in Pipelined Krylov Methods on Multi-GPU Systems

Sinan Ekmekçibaşı, James D. Trotter, Johannes Langguth, Xing Cai, Didem Unat

原文摘要

We introduce a novel triple-overlap implementation of the pipelined preconditioned conjugate gradient (Pipe-PCG) and pipelined stabilized biconjugate gradient (Pipe-BiCGStab) solvers, methods widely used in scientific applications. By leveraging a collective communication library, our approach extends conventional computation-communication overlap to concurrently execute collective operations, irregular P2P communication, and compute kernels, enabling computation-communication-communication overlap across multiple GPUs. We evaluate the design on the MareNostrum 5 (H100) and Leonardo (A100) supercomputers, comparing against PETSc and the state-of-the-art two-stream NCCL implementation using SuiteSparse matrices and three massive instances scaled up to 512 GPUs. The three-stream design outperforms the two-stream baseline on every instance, with the margin widening from 2-6% at 4 GPUs to 18-47% at 64 GPUs. At 64 GPUs, the geometric-mean speedup over the two-stream baseline is 1.33x on MareNostrum 5 and 1.23x on Leonardo for Pipe-PCG, and reaches 1.30x for Pipe-BiCGStab. In large-scale experiments, we observed a speedup up to 35% in Pipe-PCG and up to 33% in Pipe-BiCGStab compared to the two-stream design. For PETSc, the margin is even wider, up to 3.27x speedup in both Pipe-PCG and Pipe-BiCGStab. Related code for the proposed method is available online: https://github.com/ParCoreLab/aCG

cs.DC

版本更新 · v6arXiv:2603.23101

SpecXMaster Technical Report

Yutang Ge, Yaning Cui, Hanzheng Li, Jun-Jie Wang, Fanjie Xu, Jinhan Dong, Yongqi Jin, Dongxu Cui 等 21 位作者

原文摘要

Intelligent spectroscopy serves as a pivotal element in AI-driven closed-loop scientific discovery, functioning as the critical bridge between matter structure and artificial intelligence. However, conventional expert-dependent spectral interpretation encounters substantial hurdles, including susceptibility to human bias and error, dependence on limited specialized expertise, and variability across interpreters. To address these challenges, we propose SpecXMaster, an intelligent framework leveraging Agentic Reinforcement Learning (RL) for NMR molecular spectral interpretation. SpecXMaster enables automated extraction of multiplicity information from both 1H and 13C spectra directly from raw FID (free induction decay) data. This end-to-end pipeline enables fully automated interpretation of NMR spectra into chemical structures. It demonstrates superior performance across multiple public NMR interpretation benchmarks and has been refined through iterative evaluations by professional chemical spectroscopists. We believe that SpecXMaster, as a novel methodological paradigm for spectral interpretation, will have a profound impact on the organic chemistry community.

cs.LG

新论文 · v1arXiv:2610.37740

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai, Xiuxiu He, Laura Cervino, Jean Moran 等 11 位作者

原文摘要

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

eess.IV · cs.AI