跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+1205新增论文
+949其中 AI 相关
+153已有论文修订
+59新增 AI 导读

arXiv 最近完成扫描:2026-11-18 04:28 · 全站最近入库:2026-11-18 12:34各信源进度 →

统计口径与数据新鲜度

统计 2026-11-17 13:20 — 2026-11-18 13:20(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-18 04:28最近发现新增版本:2026-11-18 12:34库内论文最新更新时间:2026-11-18 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

26,054 已收录论文21,703 AI 相关7,828 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-18 04:27(北京时间)
新论文 · v1arXiv:2611.22504

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen

原文摘要

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

cs.CV · cs.LG