跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+2347新增论文
+1886其中 AI 相关
+281已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-25 03:03 · 全站最近入库:2026-11-25 01:09各信源进度 →

统计口径与数据新鲜度

统计 2026-11-24 03:52 — 2026-11-25 03:52(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-25 03:03最近发现新增版本:2026-11-25 01:09库内论文最新更新时间:2026-11-24 02:59

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

31,932 已收录论文26,401 AI 相关10,039 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 1 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-25 03:02(北京时间)
新论文 · v1arXiv:2611.28600

OKB-CFM: Observation-Keyed Barycentric Conditional Flow Matching for Unpaired Sparse-to-Dense Cardiac Shape Completion

Kangneng Zhou, Shuang Song, Yitian Zhao, Dian Song, Yujia Wang, Xinghua Zhang, Li Wang, Xi Li 等 10 位作者

原文摘要

Completing cardiac segmentations from sparse cine magnetic resonance labels is challenging because acquired planes do not uniquely determine the underlying anatomy and patient-matched dense annotations are rarely available. We propose observation-keyed barycentric conditional flow matching for completion between clinically unpaired cohorts. Independently trained variational autoencoders represent sparse observations and dense shapes. A fixed memory associates simulated sparse keys with their source dense encodings, enabling candidate retrieval within the sparse latent space. A matching network aggregates the retrieved values into a query-dependent barycentric endpoint, toward which an endpoint-conditioned flow transports the sparse encoding. Individual candidate values provide alternative completion endpoints. On 327 real unpaired inputs, the method obtains encoder-feature Fréchet and squared maximum mean discrepancy scores of 7.93 and 2.02 after scaling by 10,000 and 10,000,000, respectively, corresponding to reductions of 47.0\% and 94.2\% relative to contrastive unpaired translation. On a 34-file simulated test partition, evaluation against dense-VAE-reconstructed references yields a five-class mean Dice of 0.889, squared Chamfer distance of 6.15 square voxels, 95th-percentile surface distance of 3.88 voxels, and average symmetric surface distance of 1.50 voxels. These results characterize cohort-level feature agreement, observed-label consistency, and reconstruction under the stated reference construction. By complementing routine cine-based functional assessment with inferred multi-chamber anatomical context, this framework provides a basis for investigating how chamber morphology and spatial relationships relate to cardiac function.

cs.CV