跳到正文
研踪PaperTrail

论文库

检索计算机领域论文,按研究方向、作者或关键词筛选。

部分采集异常
正在读取账号与研究记录…

全站更新概况

+0新增论文
+0其中 AI 相关
+0已有论文修订
+0新增 AI 导读

arXiv 最近完成扫描:2026-11-30 03:10 · 全站最近入库:2026-11-26 12:29各信源进度 →

统计口径与数据新鲜度

统计 2026-11-29 03:58 — 2026-11-30 03:58(北京时间) · 点击数字查看对应简报;AI 相关包含在新增论文内。

最近完成检查:2026-11-30 03:10最近发现新增版本:2026-11-26 12:29库内论文最新更新时间:2026-11-26 08:00

每分钟刷新已保存的数据。空检查不代表采集异常;新收录可能包含历史论文。AI 导读按新增版本计数。

34,433 已收录论文28,422 AI 相关10,935 有修订112 HF 社区发现

浏览论文库

时间范围跟随排序:版本更新、本站收录或首次发表。最新收录可能包含历史论文。部分信源异常,查看状态 →

找到 6 篇论文 · 按版本更新时间排序上轮扫描起点 2026-11-30 03:08(北京时间)
新论文 · v1arXiv:2611.33671

Look at What Matters: Learning Lesion Prototypes from Severity Labels for Domain-Generalized Diabetic Retinopathy Grading

Ziyang Zhang, Juming Xiong, Yanfan Zhu, Yuechen Yang, Junchao Zhu, Zhengyi Lu, Chongyu Qu, Yiming Zhong 等 11 位作者

原文摘要

Deep learning models for diabetic retinopathy (DR) grading often generalize poorly to unseen imaging domains, in part because predictions may exploit correlations specific to source datasets rather than retinal pathology. We address this challenge by constructing grading decisions from lesion evidence learned using only image severity labels. Clinical implications of DR grades provide multiple instance constraints that guide competitive learning of lesion and background prototypes at multiple scales. An additive ordinal scoring model then predicts severity exclusively from individual lesion prototype responses, explicitly connecting learned evidence with grading decisions without a global feature classification pathway. To improve the reliability of this evidence, we introduce teacher guided preservation under image degradations and spatial regularization against persistent coordinate preferences. Across six public DR datasets under a leave one domain out protocol, our method attains a mean quadratic weighted kappa of 0.761, outperforming the strongest competing method by 0.036. Localization and prototype removal analyses show that the learned responses align with retinal lesions and contribute to grading decisions. Experiments across five other prototype architectures and under image degradations further demonstrate the generality and robustness of the approach.

cs.CV

版本更新 · v2arXiv:2611.26293

LocoMuJoCo:面向全身控制的综合模仿学习基准

LocoMuJoCo: A Comprehensive Imitation Learning Benchmark for Whole-Body Control

Firas Al-Hafez, Davide Tateo, Oleg Kaidanov, Aditya Bhatt, Artur Zelik, Zhengyi Luo, Jan Peters

AI 速读 基于摘要

LocoMuJoCo 是一个开源基准库,在统一 API 下整合 MuJoCo 与 MJX/MjWarp 后端,提供多种人形、骨骼与四足形态及动作捕捉数据,用于全身控制的模仿学习与强化学习研究。

cs.RO

查看原文摘要

LocoMuJoCo is an open-source benchmark for imitation learning (IL) and reinforcement learning (RL) on whole-body control. The library couples MuJoCo (CPU) with MJX and the MjWarp backend (GPU) under a single API, exposes 9 humanoid, 3 (musculo-)skeletal, and 4 quadruped embodiments, and ships a curated native motion-capture dataset for every humanoid, to which it can also retarget AMASS and LAFAN1. A modular plug-in architecture makes observations, rewards, control modes, terrains, and domain randomization fully interchangeable, while compact JAX implementations of many RL and IL algorithms provide JIT-compiled end-to-end training, and the companion loco-mujoco-real repository provides sim-to-real deployment. We describe the design, the SMPL-to-robot and robot-to-robot retargeting pipeline, and a usage example. LocoMuJoCo is released under MIT at https://github.com/robfiras/loco-mujoco.

版本更新 · v3arXiv:2607.00033

Learning Dexterous Manipulation Using Contact Wrench Guidance From Human Demonstration

Xinghao Zhu, Zixi Liu, Shalin Jain, Chenran Li, Milad Noori, Michael Andres Lin, Huihua Zhao, John Welsh 等 21 位作者

原文摘要

Dexterous robot manipulation can benefit from the abundance of human demonstrations, but transferring such demonstrations to robot policies remains challenging. We present Contact Wrench Guidance from Human Demonstration in Robotic Dexterous Manipulation (CHORD), a framework for long-horizon manipulation of rigid and articulated objects with reinforcement learning. The key idea is object-centric contact wrench space guidance: we represent human and robot motions by the forces and torques they can induce on the object, enabling similarity to be measured by the induced instantaneous motions. This guidance makes reinforcement learning more scalable for contact-rich dexterous manipulation. We further introduce a large-scale simulation benchmark with 4,739 bimanual dexterous manipulation tasks, constructed from motion-capture datasets and reconstructed in-house videos. Evaluated on 1,831 benchmark tasks, CHORD achieves an average success rate of 82.12%, demonstrating strong scalability. CHORD also generalizes to whole-body manipulation from hand-only and third-person demonstrations, achieving a 90.77% success rate, and the learned policies transfer to the real world in both open-loop and closed-loop settings.

cs.RO · cs.AI · cs.CV

新论文 · v1arXiv:2611.07593

TACT-KV: Tri-Axis Cosine Transform for Compressing Volumetric KV Caches in Medical VLMs

Chongyu Qu, Ritchie Zhao, Yufan He, Dong Yang, Zhengyi Lu, Junchao Zhu, Tianyuan Yao, Juming Xiong 等 15 位作者

原文摘要

Vision-language models (VLMs) applied to 3D medical scans face a structural memory wall. A single CT or MRI volume produces tens of thousands of vision tokens, and the resulting key-value (KV) cache scales linearly with both batch and context. Existing KV compression methods operate on the cache's feature or token statistics, or apply 1D and 2D transforms, leaving the three-axis spatial structure in the cache unexploited. We propose TACT-KV (Tri-Axis Cosine Transform), a calibration-free KV compression method that exploits strong spatial correlations in visual KV states along all three anatomical axes of 3D scans. This correlation concentrates the KV cache energy under a frequency-domain transform. TACT-KV applies a separable 3D discrete cosine transform to the KV cache, allocates a per-layer bit budget across frequency bins via reverse water-filling (more bits to high-energy components), and quantizes each bin with a fixed scalar codebook. We derive a close-form relation: the distortion reduction from adaptive bit allocation is dominated by the spectral concentration of the transformed cache. Across six medical VLMs and two 3D CT benchmarks, TACT-KV achieves the lowest 1-bit prediction-flip rate on eleven of twelve model and dataset pairs in our main comparison. The same advantage reproduces on four general-purpose VLMs evaluated on video tasks, indicating that the benefit of exploiting three-axis structure generalizes beyond medical imaging. At equal high-bandwidth memory (HBM), TACT-KV scales the decoding batch size on a single GPU by up to $8\times$.

cs.CV · cs.LG

新论文 · v1arXiv:2611.05925

3D Banff Glomerulitis Scoring for Kidney Transplant Pathology: Feasibility Study for Volumetric Quantification

Yanfan Zhu, Junchao Zhu, Ruining Deng, Shilin Zhao, Yu Wang, Yaohong Wang, Yuechen Yang, Chongyu Qu 等 15 位作者

原文摘要

Quantifying glomerular inflammation in kidney-transplant biopsies is traditionally performed on single whole-slide sections using the Banff "most-severe section" rule, despite the inherently three-dimensional nature of lesion distribution. This 2D based assessment might lead to instability when inflammation varies across slices. This paper reports a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring into three dimensions. To this end, we propose a 3D Banff lesion-scoring framework that aligns serial sections, reconstructs glomerular identities across depth, and integrates inflammatory-cell counts in 3D under three scoring strategies: Compatible, Volumetric, and Deduplicated Volumetric. In the experiments, glomerulitis (g-scores) was used as an example Banff metric and applied to multi-section renal allograft biopsies. Our findings indicate that 3D Banff g-scores are more consistent across sections and, under the semi-automatic setting, the Volumetric strategy correlates more strongly with clinical biomarkers than traditional 2D scores. These results show that 3D volumetric quantification offers promising added value, underscoring the potential benefit of 3D-aware Banff scoring for kidney transplant pathology.

cs.CV

新论文 · v1arXiv:2610.39151

STRATA: Reinforcement-driven Active Sampling with Tri-paradigm Adaptation for Efficient 3D Spatial Transcriptomics

Junchao Zhu, Ruining Deng, Chongyu Qu, Zhengyi Lu, Yanfan Zhu, Yuechen Yang, Yu Wang, Shilin Zhao 等 10 位作者

原文摘要

Spatial transcriptomics (ST) enables joint characterization of tissue morphology and gene expression. However, 3D volumetric ST acquisition remains expensive. AI-driven methods offer a low-cost alternative but remain limited in accuracy, while recent 2D section-wise ST acquisition still rely on dense grid sampling, resulting in redundant measurements and undersampling of biologically informative regions. To bridge the gap, we propose STRATA, a reinforcement-driven active sampling framework with tri-paradigm adaptation for reconstructing dense 3D transcriptomic maps from sparse voxel-wise ST acquisition. STRATA constructs a 3D graph integrating H&E morphology with single-cell priors and employs a reinforcement learning agent to estimate morphological sparsity and transcriptomic informativeness, enabling budget-aware selection of informative spots. Given these sparse measurements, an adaptive tri-paradigm predictor combines retrieval, regression, and cross-layer imputation through lightweight fusion, dynamically weighting their contributions. Experiments across datasets demonstrate improved sampling efficiency and accuracy, particularly under low-budget settings. Code is available at https://github.com/Junchao-Zhu/STRATA.

cs.CV