Physics-Aware Zero-Shot Learning for Low-Dose CT from a Single Sinogram

首次提交 2025-04-11 01:42
版本更新 2026-11-17 12:19
雷达观测 2026-11-18 19:43
arXiv ↗PDF ↗

摘要

Low-dose computed tomography (CT) imaging remains a persistent challenge, especially under heterogeneous acquisition conditions. Zero-shot learning, which enables models to learn directly from individual images without external supervision, represents a compelling approach to mitigate distribution mismatches arising from variations in scanner hardware, imaging protocols, and patient demographics. However, most existing zero-shot approaches employ down-sampling operations that reduce spatial resolution and cause domain shifts, which become particularly evident when applied to raw sinogram data. Here, we propose a physics-aware zero-shot CT denoising framework to exploit the conjugate symmetry property intrinsic to CT sinograms. Conjugate X-ray pencil beams traverse identical anatomical paths and ideally yield the same expected attenuation values but with independent noise realizations. By randomly mapping sinogram values between conjugate-ray pairs, we synthesize structurally consistent yet noise-diverse sinogram pairs, enabling self-supervised network training without external data. The resulting lightweight denoising network demonstrates strong generalization across low-dose simulation, clinical helical CT, and preclinical photon-counting CT datasets. Quantitative and qualitative results demonstrate competitive denoising performance, with favorable noise suppression and structural preservation across diverse acquisition settings. This work establishes a generalizable and data-efficient paradigm for CT denoising that integrates physical redundancy into learning-based image reconstruction. The code for the proposed method is openly available at: https://github.com/shiyongyi/Physics-Aware-Zero-Shot-CT-Sinogram-Denoising

作者备注:10 pages, 5 figures

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

本站首次收录为 v2,暂无更早版本可对照。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-11-17 12:19 · 最新观测版本

Physics-Aware Zero-Shot Learning for Low-Dose CT from a Single Sinogram

Low-dose computed tomography (CT) imaging remains a persistent challenge, especially under heterogeneous acquisition conditions. Zero-shot learning, which enables models to learn directly from individual images without external supervision, represents a compelling approach to mitigate distribution mismatches arising from variations in scanner hardware, imaging protocols, and patient demographics. However, most existing zero-shot approaches employ down-sampling operations that reduce spatial resolution and cause domain shifts, which become particularly evident when applied to raw sinogram data. Here, we propose a physics-aware zero-shot CT denoising framework to exploit the conjugate symmetry property intrinsic to CT sinograms. Conjugate X-ray pencil beams traverse identical anatomical paths and ideally yield the same expected attenuation values but with independent noise realizations. By randomly mapping sinogram values between conjugate-ray pairs, we synthesize structurally consistent yet noise-diverse sinogram pairs, enabling self-supervised network training without external data. The resulting lightweight denoising network demonstrates strong generalization across low-dose simulation, clinical helical CT, and preclinical photon-counting CT datasets. Quantitative and qualitative results demonstrate competitive denoising performance, with favorable noise suppression and structural preservation across diverse acquisition settings. This work establishes a generalizable and data-efficient paradigm for CT denoising that integrates physical redundancy into learning-based image reconstruction. The code for the proposed method is openly available at: https://github.com/shiyongyi/Physics-Aware-Zero-Shot-CT-Sinogram-Denoising

查看此版本解读 →查看此版本原文 ↗