跳到正文
研踪PaperTrail
← 研踪 PaperTrail

arXiv:2506.04467 · v2

Generalizable dose denoising using diffusion transformer framework for pencil beam scanning proton therapy

首次提交 2025-06-05 05:37
版本更新 2026-10-29 04:41
雷达观测 2026-10-30 11:25
arXiv ↗PDF ↗

摘要

Background and purpose: Intensity-modulated proton therapy (IMPT) enables conformal dose delivery for head and neck (H&N) cancers. However, its sensitivity to inter-fractional anatomical changes motivates online adaptations, where rapid and accurate Monte Carlo (MC) dose calculation remains a major bottleneck. Low-statistics MC simulations reduce computation time but introduce noise. This study aimed to develop a diffusion-transformer framework to recover high-statistics dose distributions from noisy MC simulations. Materials and methods: A diffusion-transformer-based dose denoising framework was developed. Eighty H&N patients were used for training and additional 10 H&N patients and 30 patients with lung, breast, and prostate cancers (10 per site) were used for evaluation. Noisy and high-statistics dose maps were generated using MCsquare. The model was trained using noisy dose maps and CT images as inputs and high-statistics dose maps as ground truth, with mean squared error, residual, regional mean absolute error (MAE), and dose-volume histogram (DVH) losses. Performance was evaluated using MAE, 3D gamma passing rates, and DVH indices. Results: Mean whole-body MAE ranged from 0.08 +/- 0.06 to 0.20 +/- 0.11 Gy (Relative Biological Effectiveness, RBE) (RBE = 1.1) across test cohorts. Mean whole-body 3 %/2 mm gamma passing rates ranged from 95.8 +/- 0.8 % to 97.6 +/- 0.9 %. DVH indices from high-statistics and predicted dose distributions showed close agreement for clinical target volumes and organs of interest. Conclusions: The diffusion-transformer-based framework denoised low-statistics MC dose distributions. Despite being trained on H&N data, the model generalized to lung, breast, and prostate cohorts without retraining.

AI 论文解读

基于摘要 · 非全文审阅

此版本尚未生成 AI 解读。解读由后台任务生成并按论文版本保存,登录后共享已有结果。

版本差异

目前只观测到一个版本,无法比较变化。之后收录新版本时,会在这里对照标题、作者、分类和摘要。

观测到的版本

相邻记录可能跳过中间版本;首次发现 v2 及以上也会标为版本更新。

v2 · 2026-10-29 04:41 · 最新观测版本

Generalizable dose denoising using diffusion transformer framework for pencil beam scanning proton therapy

Background and purpose: Intensity-modulated proton therapy (IMPT) enables conformal dose delivery for head and neck (H&N) cancers. However, its sensitivity to inter-fractional anatomical changes motivates online adaptations, where rapid and accurate Monte Carlo (MC) dose calculation remains a major bottleneck. Low-statistics MC simulations reduce computation time but introduce noise. This study aimed to develop a diffusion-transformer framework to recover high-statistics dose distributions from noisy MC simulations. Materials and methods: A diffusion-transformer-based dose denoising framework was developed. Eighty H&N patients were used for training and additional 10 H&N patients and 30 patients with lung, breast, and prostate cancers (10 per site) were used for evaluation. Noisy and high-statistics dose maps were generated using MCsquare. The model was trained using noisy dose maps and CT images as inputs and high-statistics dose maps as ground truth, with mean squared error, residual, regional mean absolute error (MAE), and dose-volume histogram (DVH) losses. Performance was evaluated using MAE, 3D gamma passing rates, and DVH indices. Results: Mean whole-body MAE ranged from 0.08 +/- 0.06 to 0.20 +/- 0.11 Gy (Relative Biological Effectiveness, RBE) (RBE = 1.1) across test cohorts. Mean whole-body 3 %/2 mm gamma passing rates ranged from 95.8 +/- 0.8 % to 97.6 +/- 0.9 %. DVH indices from high-statistics and predicted dose distributions showed close agreement for clinical target volumes and organs of interest. Conclusions: The diffusion-transformer-based framework denoised low-statistics MC dose distributions. Despite being trained on H&N data, the model generalized to lung, breast, and prostate cohorts without retraining.

查看此版本解读 →查看此版本原文 ↗